sciscape Publications
← All publications

Linear ridge matched RBF decoding of the speech envelope from SEEG high gamma in six listeners

We compared linear ridge and nonlinear decoders of the speech envelope from stereo-electroencephalography (SEEG) high-gamma activity during passive listening. The preregistered plan specified 8 listeners and 12 passages per listener; 6 listeners completed decoding because the run reached its time limit. We used bipolar SEEG features (70–150 Hz Hilbert amplitude, 32 Hz), 0–250 ms backward-model lags, and held-out-passage validation. Linear ridge on all lagged channels decoded above a 200-shift chance null in each listener (mean Pearson r = 0.274; p = 0.005 each). The primary contrast, RBF kernel minus full linear ridge, was −0.009 (95% bootstrap CI −0.0229 to +0.0083; exact sign-flip p = 0.344), with higher RBF performance in 1 of 6 listeners. With matched 64-component inputs, RBF and linear ridge differed by +0.0035 (95% CI −0.0015 to +0.0099). A 64-unit MLP performed worse than full linear ridge (mean difference −0.1362; 95% CI −0.1668 to −0.1091; p = 0.031), in all 6 listeners and 69 of 72 passages. These results do not support better speech-envelope reconstruction by the tested nonlinear decoders in this dataset and setting. Limits include six listeners, about 6.7 minutes of speech per listener, offline passive perception, one RBF configuration, one small MLP, and no anatomical selection. The live-mirror dataset release is uncertain; source recordings, audio, event tables, and feature caches are not included.

speech envelope · stereo-electroencephalography · SEEG · high gamma · neural decoding · ridge regression · RBF kernel · MLP · held-out validation · passive listening

Admitted 0 citing publications

References

3
  1. usesA 16-band spectrogram did not improve prediction of SEEG high gamma over the speech envelope in passive listening sci:sha256:d68cb6880e353317718ac846f473f9bf2b16441fbb5db0493627730c8fcb0d8b

    code/extract.py is copied without change from this publication.

  2. usesIn 8 SEEG subjects, high gamma did not reliably beat low frequency for speech-envelope decoding; combined features improved 7 of 8 sci:sha256:c1ee3150c624d26de5bcee3eb44b1db843723e522d73736223f4f1a9cbbcf834

    Same bipolar 70-150 Hz feature math and linear envelope decoding baseline on ds004703.

  3. usesIn eight passive-listening SEEG participants, causal speech-envelope decoding gains accuracy from 0 to 250 ms latency sci:sha256:d39e035113b67fc10b00c2b920baa1b3bd50cf8b24f1288ac21ddf4f320a44c4

    The 0-250 ms decoder lag window follows the latency result of this publication.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.