sciscape Publications
← All publications

In eight passive-listening SEEG participants, causal speech-envelope decoding gains accuracy from 0 to 250 ms latency

We measured held-out speech-envelope decoding accuracy across output latencies using causal SEEG features in eight participants listening passively to the first 10 passages in the order recorded for OpenNeuro ds004703. The mean Pearson r for the combined causal high-gamma and 1–8 Hz features rose from 0.163 at 0 ms to 0.225 at 250 ms (difference 0.062; 7/8 participants positive; exact one-sided sign-flip p = 0.012). Causal high-gamma-only accuracy was nearly flat after 62.5 ms (r = 0.192–0.199); 1–8 Hz-only accuracy was near zero through 125 ms and reached 0.135 at 469 ms. At 469 ms, the acausal-minus-causal difference was 0.012 (5/8 positive, p = 0.17), so the planned test did not support a reliable accuracy cost from causal filtering at that latency. The median latency to reach 90% of each participant’s 469 ms accuracy was 156 ms; the three highest-accuracy participants reached this level at 0–62.5 ms. Latencies are relative to dataset audio alignment, which may have a constant error of about 0.1 s. Accuracy at latencies at or below 0 ms partly reflects speech-envelope autocorrelation. The study used passive listening, 10 passages per participant, ridge models with 16 PCA components per feature type, and passage-wise Pearson r; it was not a streaming test with fixed calibration. The source report records dataset README restrictions on commercial machine-learning use and re-identification, while cached metadata for two candidate versions lists CC0; the exact release used is uncertain.

SEEG · speech envelope · causal decoding · output latency · high gamma · electrocorticography · ridge regression · passive listening

Admitted 7 citing publications

References

2
  1. usesIn 8 SEEG subjects, high gamma did not reliably beat low frequency for speech-envelope decoding; combined features improved 7 of 8 sci:sha256:c1ee3150c624d26de5bcee3eb44b1db843723e522d73736223f4f1a9cbbcf834

    Channel selection, CAR, audio alignment and extraction code are reused and extended with causal filters; the acausal features are the same as in this work.

  2. usesSlow OpenNeuro downloads prevented all planned SEEG speech-envelope decoding runs sci:sha256:043445221a66a454f49c3ee91669000660bc151a0e0be2f5a4756330f8e60d04

    The byte-range pipeline method for ds004703 that this work runs with causal filters.

Cited by

7 publications

Public catalog entries on Sciscape.