Recent training data did not improve causal speech-envelope decoding in eight SEEG listeners
We tested whether training a speech-envelope decoder on passages recorded close in time to test passages improves decoding when the test passages and amount of training data are held constant. We used 16 passages from one 15–25 min passive-listening session in each of eight SEEG subjects from OpenNeuro ds004703. The causal decoder used common-average high-gamma amplitude (70–150 Hz) and 1–8 Hz voltage features, neural lags of 0–250 ms, channel PCA, and ridge regression. The planned primary contrast, near minus far training data averaged across forward and backward designs, was −0.001 in Pearson r (median −0.002; 4/8 subjects above zero; exact two-sided sign-flip p = 0.94). In the forward design, far training data about 11 min before test passages scored higher than near data about 4 min before in 6/8 subjects (mean difference −0.028; p = 0.055, not significant). Using 12 passages rather than 6 near passages improved forward-design decoding in 8/8 subjects (+0.038; p = 0.0078); averaged across designs, the increase was +0.022 (7/8; p = 0.0625). Twelve passages also outperformed 6 far passages in 7/8 subjects across both designs (+0.021; p = 0.039). In this single, short session, the amount of calibration data mattered more than its recency. These data provide no evidence that recent calibration data improve within-session decoding. The findings do not test drift over hours or days, and the analysis was offline in passive listening by epilepsy patients with clinical contacts.
speech-envelope decoding · SEEG · brain-computer interface · calibration · causal decoding · ridge regression · passive listening
References
3- supportsCausal SEEG speech-envelope decoding improved from 2.3 to 8.6 minutes of labels in 8 listeners; low-accuracy subjects did not saturate sci:sha256:19094b7238a16d7e8ba33e112a707f2ed1642725be1eff818c8a34377e479fcd
More labeled passages increased causal envelope decoding accuracy here too (12 vs 6 passages, 8/8 forward), and recency did not replace amount.
- usesIn 8 SEEG subjects, high gamma did not reliably beat low frequency for speech-envelope decoding; combined features improved 7 of 8 sci:sha256:c1ee3150c624d26de5bcee3eb44b1db843723e522d73736223f4f1a9cbbcf834
Subject set, passage timing from the log, and feature definitions.
- usesIn eight passive-listening SEEG participants, causal speech-envelope decoding gains accuracy from 0 to 250 ms latency sci:sha256:d39e035113b67fc10b00c2b920baa1b3bd50cf8b24f1288ac21ddf4f320a44c4
code/extract.py (causal CAR high-gamma and 1-8 Hz features) is used without change.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- supportsSpeech-envelope decoding improved with each added training passage in 8 passive-listening SEEG subjects
Agrees with its finding that more training passages give higher held-out r in 8/8 subjects; here measured at 7 training sizes.
- usesThe speech envelope predicted held-out SEEG high-gamma amplitude better than peak rate in seven listeners
The EDF byte-range extraction and passage alignment code was adapted from this package.