Corrected conformal calibration by scan date returned all selected SEEG pairs at 90 percent in seven ds003498 patients
We tested candidate sets for high frequency oscillation count lists in public SEEG data. OpenNeuro ds003498 version 1.1.1 supplied 135 records from seven patients. Each record had 300 seconds. The target list kept all ties at the top 20 percent count boundary. At the 90 percent level, calibration by scan date returned all selected pairs. The corrected quantile needs nine calibration dates before it can select fewer than all pairs. Only zero to four calibration dates remained after fitting and target dates were removed. Calibration by record retained 73.78 percent of pairs under equal patient weights. Its descriptive 95 percent patient bootstrap interval was 49.98 to 92.03 percent. The package preserves source marks, complete primary sets, code, a rank proof, and nine fixed checks. Independent parsing checked every count row. A separate run matched all 15 numeric output files exactly. The exhaustive coverage result follows from a rank identity. It does not validate future coverage. A future guarantee needs exchangeable calibration and target units conditional on fitting data. The target is a detector-count list. The study does not measure tissue labels or clinical accuracy.
conformal prediction · stereoelectroencephalography · high frequency oscillations · whole-list prediction · calibration · uncertainty quantification
References
6- usesPoisson bands at a common rate for overlapping HFO counts failed more between records than within records in 135 SEEG sleep records from seven patients sci:sha256:fa29d36b7755d5d7ec5232f6b56bd09a067c17b207c1fb682831ec38ccd838e1
Its count variation result motivated the whole-list uncertainty question. We used the same cohort. We did not reuse its fitted bands or score tables.
- usesUnder independent patient resampling, the 95 percent interval for mean HFO count prediction gain from a 60 second update included zero in seven SEEG patients sci:sha256:da24ae93b18873ed5d6b75a7db44c533c2f1b97dbbb0889aa7a260633d0c5942
The checked source archive, resolved headers, count parser, and contact aliases supplied the data and count rules. We did not reuse its prediction scores.
- usesdoi:10.18112/openneuro.ds003498.v1.1.1
The analyzed detector-mark records came from this exact OpenNeuro release.
- usesdoi:10.6080/K06Q1VD5
The OpenNeuro records derive from the CRCNS iEEG-1 source dataset.
- supportsdoi:10.1038/s41598-017-13064-1
The source paper identifies the depth-only patients and describes the sleep and detector selection used to define the tested subset.
- doi:10.48550/arXiv.2107.07511
Background reference for the standard corrected conformal quantile and rank guarantee.
Cited by
0 publicationsPublic catalog entries on Sciscape.