Poisson bands at a common rate for overlapping HFO counts failed more between records than within records in 135 SEEG sleep records from seven patients
This study tested exact Poisson count bands in public SEEG sleep data from OpenNeuro ds003498 v1.1.1. It used 135 records from seven patients and compared equal 150-second parts of the same channel pair. The primary count was the number of marks where a ripple overlapped a fast ripple. The band assumes independent counts at a common rate. The analysis removed the exact expected failure from discrete counts. Excess failure was 5.70 percentage points greater between records than within a record. All seven patients showed an increase. The exploratory 95 percent patient bootstrap interval was 2.71 to 9.28 points. Observed band coverage was 97.64 percent within records and 91.90 percent between records. The exact model references were 99.24 and 99.21 percent. The package contains source marks, count tables, code, hashes, results, and instructions. The result applies to released detector marks in this reused small cohort. It establishes no neural cause or clinical accuracy.
Poisson count bands · high frequency oscillations · stereoelectroencephalography · sleep · count calibration · epilepsy
References
5- usessci:sha256:74e22fdac1f333c2b0ddb2a290f381a26fb548555b4502c3a28eb34f5d53248c not known to Sciscape
The pinned source archive and retrieval code supply the public source files. The count variation result motivated the new count band check. Every archived source hash was checked. All 185 public event files were retrieved again.
- usessci:sha256:a22be20f9664505ea33080cefb407ff7b6665b5b75e6cc0193ba4ef160713581 not known to Sciscape
The source parser and structural pair selection were adapted for this study. The contact list result motivated the comparison within and between equal record parts. The new analysis uses the same cohort and provides no independent patient confirmation.
- usesdoi:10.18112/openneuro.ds003498.v1.1.1
The analyzed detector marks and records came from OpenNeuro ds003498 version 1.1.1.
- doi:10.6080/K06Q1VD5
- supportsdoi:10.1038/s41598-017-13064-1
The source paper identifies the depth cohort and describes the sleep and contact selection used to define the source dataset.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesCorrected conformal calibration by scan date returned all selected SEEG pairs at 90 percent in seven ds003498 patients
Its count variation result motivated the whole-list uncertainty question. We used the same cohort. We did not reuse its fitted bands or score tables.