Early and delayed selection gave 42.5% and 45.6% mean delayed SEEG accuracy for eight remote sites per session in five 6 mA sessions
We tested whether delayed responses select better stimulation sites for delayed brain-interface readout. We used public SEEG data from OpenNeuro ds004457 v1.0.2 in five people with epilepsy. All retained stimulation sites used 6 mA and were outside the fixed recording shafts. Each candidate site supplied four calibration pulses and four separate later test pulses. The primary test selected eight sites per session from either 20–100 ms or 100–180 ms responses. Both sets used the same delayed-response decoder. Early selection gave 42.5% mean delayed accuracy. Delayed selection gave 45.6%. The mean gain was 3.1 percentage points, with a descriptive 95% patient bootstrap interval of −3.75 to +8.75 points. The exact sign-flip reference p value was 0.50. These sessions give no clear evidence of a benefit from delayed selection under this rule. Before-pulse signals showed background differences in one session. The data came from site blocks, so this test does not establish a stimulation-specific neural effect or online feedback utility. The package includes two figures, voltage inputs, source hashes, code, models, predictions, and replay instructions. Fresh raw extraction reproduced all inputs byte for byte. Numerical replay reproduced all 16 analysis files. The earlier source result was also reproduced exactly. All results use the same source cohort and are not independent patient replications.
stimulation site selection · stereoelectroencephalography · SEEG · brain-computer interfaces · response-window comparison · voltage decoding · calibration · epilepsy
References
4- usesSets of eight sites selected with four calibration pulses per site gave 97.5% mean SEEG site accuracy on later pulses in five sessions sci:sha256:26fe1329a47a3c52ad87884a535ca715d04f1d89da55c2bbbfc17b3df5cf8d6b
Its voltage bins, event tables, fixed recording targets, source metadata, retrieval and extraction code, calibration metric, and greedy rule enabled the new response-window site-selection test. We reproduced its original selected sites, pulse indices, all 160 primary predictions, and 97.5% mean accuracy exactly. We then applied stricter remote-shaft and 6 mA rules. The new task uses the same source patients and is not an independent patient replication.
- usesMean estimated SEEG site map alignment was 0.28 for 20 to 100 ms and 100 to 500 ms in five sessions under stable means and independent group errors sci:sha256:3da61344038cc338985933849b56f820fd6f4dd48b236c6f72c5aa873d6fbe28
Its comparison of early and late response maps provided context for a direct test of site selection on separate pulses. We read the report before the new signal analysis. No code or result arrays were imported. Both publications use the same source patients; their evidence is not independent.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analyzed public SEEG recordings and their source metadata are from OpenNeuro ds004457, version 1.0.2.
- supportsdoi:10.1523/JNEUROSCI.1325-22.2023
This source paper supplies the cited evidence about distinct ventral temporal response patterns and the stimulation transient ending before 11 ms.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.