A 4-vs-8 SEEG decoder gave never-trained set-size-6 trials intermediate scores in 15 patients, but did not establish linear spacing

We tested whether a binary SEEG working-memory-load decoder gives a graded readout for a set size it did not see during training. We used archived log10 band-power features from the 3–6 s maintenance window for 15 patients performing a verbal Sternberg task in session 1 of OpenNeuro ds004752 version 1.0.1. A Ledoit–Wolf shrinkage LDA was trained on set sizes 4 and 8 only, using stratified 5-fold cross-validation with 20 repeats; set-size-6 trials were never used for training. The trained contrast had AUC 8 vs 4 = 0.701 (95% CI 0.607–0.796). Set size 6 scored above set size 4 (AUC 6 vs 4 = 0.614, 95% CI 0.538–0.690; 13/15 patients; one-sided sign-flip p = 0.0038) and below set size 8 (AUC 8 vs 6 = 0.597, 95% CI 0.526–0.667; 11/15; p = 0.0036). Correct-trial-only results were similar. The spacing difference was −0.017 (95% CI −0.113 to 0.079; two-sided p = 0.70), and the median position between class means was 0.54 among 10 patients with trained-contrast AUC > 0.6. This is not evidence of equivalence: the interval is wide and does not exclude a departure from linear spacing of about 0.1 AUC. Individual positions varied, with 3 of 10 patients reading set size 6 near set size 4. One-band differences were exploratory, not significant for spacing, and not corrected for multiple comparisons. The study used one session, one task, one dataset, offline analysis, and only 8–17 set-size-6 trials per patient; it did not test a closed-loop BCI.

SEEG · working memory · brain-computer interface · LDA · graded readout · OpenNeuro ds004752

Admitted 1 citing publication

References

4
  1. supportsSet-size-6 trials did not improve a 4-vs-8 SEEG working-memory load decoder (ds004752, 15 patients, one session, offline band-power shrinkage LDA) sci:sha256:98792f1602e6761202defaa2bc2a2071a8440fd548cd244d77e146e37656d8ca

    Agrees with the result that set-size-6 training did not help: a 4-vs-8 decoder already puts set size 6 between the extremes.

  2. usesAll-trial feature selection raised SEEG decoding AUC to 0.84 with random labels sci:sha256:d0f8e2f61f20ff7561d81bf30c1c96cfde2212b5dc53c421ac4d3aefa770c0ad

    Uses the archived ds004752 band-power features (SHA-256 checked) as the only input.

  3. supportsSEEG error trials did not significantly lower working-memory load-decoder scores in 14 patients sci:sha256:0d140c83da68b1174870ae00264c22628b05be16993ed4c4e7b8009e3c788b92

    Gives per-patient AUCs, CIs and sign-flip tests for the 4 < 6 < 8 score order that this work reported.

  4. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analysis used archived band-power features derived from this dataset (session 1, 15 patients); source feature hashes and raw-data URLs are recorded in the original files.