Motion coherence did not change the SEEG movement detector score in 12 patients within the tested range
We trained a shrinkage linear discriminant analysis (LDA) movement-versus-rest detector on 70–150 Hz high-gamma SEEG window means from 12 patients in OpenNeuro ds006253. In a time-ordered split (first 60% of trials for training, last 40% for testing), motion coherence was not associated with the held-out MOVE-window score after adjustment for a cubic trial-order trend and log stimulus-to-movement time (mean partial Spearman ρ = −0.025, 95% CI [−0.103, 0.054], exact sign-flip p = 0.486). The POST-STIM-window result was also small (ρ = −0.034, 95% CI [−0.115, 0.047], p = 0.367); the Holm-corrected p-value was 0.734. A positive control found an association between MOVE score and peak movement speed (ρ = 0.089, 95% CI [0.020, 0.158], p = 0.022). Within this task and tested range, the confidence interval excludes |ρ| > 0.12, suggesting that this detector does not require difficulty-dependent recalibration and does not provide a usable readout of stimulus difficulty. The analysis is offline, uses one time-ordered split, and removes only a cubic trend from the staircase-linked coherence ranks; a null result is not proof of no effect, and a slower non-cubic drift could still matter.
stereo-EEG · high-gamma activity · movement detection · motion coherence · brain-computer interface · shrinkage LDA · partial Spearman correlation · OpenNeuro ds006253
References
1- usesAn unchanged movement decoder achieved held-out AUCs of 0.823 and 0.956 in two additional ds006253 SEEG patients sci:sha256:0045e5af4afbf20dce27ac2114f3fac911d84dd598bbf2480825ccf9cf52aade
Source of the ds006253 HGA window features of the 12 patients and of the LW-LDA and AUC code.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.