A fixed spectral correction did not detect a median beta shift in two-second post-stimulation SEEG windows from 21 patients
This study tested signed 13–30 Hz beta changes in marked two-second post-stimulation SEEG windows from all 35 public records in 21 patients in OpenNeuro ds006519 v1.0.0. A fixed spectral correction did not detect a common median change: +0.051 dB (patient bootstrap 95% interval −0.359 to +0.292 dB; two-sided exact sign test p = 1.000). Correction changed 9 of 21 post-window patient-summary signs and 10 of 21 baseline signs. Artificial probes showed that the correction removes uniform gain and log spectral slope changes, while a change confined to reference bins can change corrected beta with beta power unchanged. All raw source files passed recorded size and SHA-256 checks, and an independent FFT rebuild reproduced all 35 spectra. The result is limited to these records, windows, and feature definitions. It does not establish a zero shift, a causal stimulation effect, or improved BCI decoding.
SEEG · beta power · spectral correction · brain-computer interface · cortical stimulation · power spectral density · signal processing
References
4- usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489
This study uses its 35 saved spectra, source metadata, and hash-checked raw-file recipe. It independently rebuilds all spectra and adds a signed beta contrast, patient summaries, baseline comparisons, and artificial spectrum probes.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
Source dataset used: all 35 public SEEG records from OpenNeuro ds006519 v1.0.0.
- doi:10.1038/s41593-020-00744-x
- usesdoi:10.1016/j.neuroimage.2026.121822
The source paper describes the clinical motor-stimulation data underlying the analyzed SEEG dataset.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesA fixed spectral contrast reduced absolute 70 to 110 Hz log-power change in marked post-stimulation SEEG windows from 21 people
This publication used a fixed beta spectral correction in the same cohort. It supplied the method context for the high-gamma stability question.
- usesChanges in 4–40 and 70–150 Hz slopes had 52 percent median sign disagreement in marked post-stimulation SEEG windows of two seconds from 21 patients
Its corrected beta study supplied the low-flank sensitivity idea. The current study tests range-specific change signs in the same patient sample.