sciscape Publications
← All publications

Shaft access raised expected SOZ balanced accuracy for a fixed HFO rule in 18 SEEG records with equal source counts

We tested whether source channels on the test electrode shaft change an SOZ label score. SOZ means seizure onset zone. We used two high-frequency oscillation detector counts from 18 public SEEG sleep records. SEEG means stereoelectroencephalography. The sample had 1,285 bipolar channels. A fixed rule copied the nearest source label in log count space. Both source procedures used equal source counts. Both main procedures excluded channels that shared either raw contact with the test channel. We averaged exactly over fair source subsets and distance ties. Mean expected balanced accuracy was 55.07 percent with access to the test shaft. It was 50.41 percent after whole shaft exclusion. The difference was 4.66 percentage points. Its descriptive 95 percent patient bootstrap interval was 1.77 to 8.23 points. The contrast after subtraction of a uniform source control was 3.47 points. All six planned checks had positive mean differences. Two patients supplied 54.6 percent of the main signed difference sum. Sensitivity was low under both procedures. This result concerns the fixed rule and released labels in this cohort. It does not establish clinical benefit or accuracy in new patients. The package preserves source bytes, retrieval pins, code, weights, results, figures, and reproduction instructions. Independent checks passed. Eight output files matched a full offline repeat.

seizure onset zone · high-frequency oscillations · stereoelectroencephalography · source selection · balanced accuracy

Admitted 0 citing publications

References

3
  1. usesBipolar SEEG shape at 20 to 100 Hz gave 55.78 percent expected accuracy for shared fair random shaft labels in 33 patients after target contact exclusion sci:sha256:a678a731837abfc0a1f6c2968be5dff76b245bf85099b950f9f434fc3d4d43a6

    This publication supplied the exact source subset design with equal source counts. We wrote new code for clinical SOZ labels and HFO count features in another cohort. Its random-label accuracy formula was not used.

  2. usesUnfiltered STE and MNI event maps differed more than adjacent 10-minute samples in the first hour of 17 SEEG sleep records sci:sha256:c3924a4d1005d065d0b27dd0614e3c0ad68882a5aab501edf7b37602f8069c28

    We used the pinned public event files, source metadata, EDF headers, and manifest from this publication. They allowed offline count extraction and fresh public hash checks. We calculated new SOZ source exclusion scores in the same cohort.

  3. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    This study analyzes event marks, clinical channel labels, metadata, and EDF headers from OpenNeuro ds005398 version 1.1.3.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.