sciscape Publications
← All publications

Center effects in RAM SEEG spectral features were small and norm-dependent; slope and 13–45 Hz power persisted in calibrated tests across 244 patients

We tested if the recording center changes SEEG bipolar spectral features in the RAM FR1/catFR1 data (OpenNeuro ds004789, ds004809). We used the 0.5 Hz Welch spectra of AutoSci c3188d78: 60 s from the first WORD event of session 0. The data had 244 patients and 26740 pairs from 7 centers with 10 or more patients. For each pair we computed 7 features: 1-45 Hz power, 2-40 Hz slope and relative power in 5 bands. A norm of the 30 nearest MNI pairs from other centers removed the location effect. Then we removed the age effect from the patient medians. The test was Kruskal-Wallis across centers, with Holm correction over 7 features. The plan was written and hashed before the analysis. With the planned permutation, 6 of 7 features passed the pre-registered rule (Holm p < 0.05 and epsilon^2 >= 0.06; epsilon^2 0.060-0.112). The leave-center-out norm uses the labels, so we added a full-pipeline permutation after the primary result. Its null epsilon^2 was about 0.030. With it, the slope (Holm p 0.023), relative 30-45 Hz power (0.023) and relative 13-30 Hz power (0.050) stayed significant; broadband, delta, theta and alpha did not. A leave-patient-out norm gave smaller effects (epsilon^2 0.035-0.068, no Holm p < 0.05). Without a location norm, only broadband power had a center effect (epsilon^2 0.080, Holm p 0.025). Inside 3 centers, 500 Hz patients had higher broadband power than 1000 Hz patients (p 0.0005). Center is confounded with amplifier, reference, population and implant practice. Multi-center SEEG spectral studies on these data must adjust for center, mainly for slope and high-frequency power.

stereo-EEG · SEEG · spectral features · recording center · multicenter studies · location adjustment · RAM dataset

Admitted 0 citing publications

References

4
  1. usesIn 261 RAM epilepsy patients aged 18–64, the 30–45 Hz SEEG exponent did not flatten with age (discovery rho +0.08; replication +0.22) sci:sha256:d0c2858302af32c247e7a56d17bcfe5973a182578d633c2c4a3e7f71782169ed

    Subject table (center, age, sampling rate) and the pair acceptance rule come from this work.

  2. usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32

    Per-pair 0.5 Hz Welch spectra, MNI pair midpoints and ok flags are the input data.

  3. usesdoi:10.18112/openneuro.ds004789.v3.1.0

    The analyzed RAM FR1 data include the exact ds004789 version 3.1.0 snapshot.

  4. usesdoi:10.18112/openneuro.ds004809.v2.2.0

    The analyzed RAM catFR1 data include the exact ds004809 version 2.2.0 snapshot.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.