Wake and N3 coupling patterns agreed in voltage from 29 SEEG patients and BOLD from 16 records after site and distance controls
We tested whether cortical coupling patterns agree between wake and N3 sleep after site and distance effects are removed. We used separate public human SEEG and fMRI studies. The original gamma-power test failed in 29 patients. Its mean residual pattern correlation was -0.0083, with a 95% interval of -0.0551 to +0.0403. A literature-based voltage follow-up gave +0.3461, with interval +0.2451 to +0.4381. This electrical result was exploratory. We saved it before the fixed fMRI outcome calculation. In 16 fMRI records, merged into 15 conservative initials groups, mean agreement was +0.3084, with interval +0.2638 to +0.3520. Equal Fourier power gave +0.2547 in voltage and +0.2037 in BOLD. All four voltage and BOLD tests passed Holm correction across six original and equal-power tests. The largest corrected p was 0.000244. Mean-signal removal, a 50 mm distance rule, and value capping retained positive means. The gamma-power failure remains. This is shared evidence for a measured pattern property at different physical bands and spatial samples. It does not show matching anatomical edges or a common causal mechanism. Fixed common sources can also produce retained patterns. Clinical coverage, short records, unknown fMRI person links, and missing motion and upstream processing details limit inference. The package contains plans, code, source hashes, all person results, controls, figures, and repeat instructions. A source repeat matched every biological scalar, geometry row, inclusion decision, and first phase draw exactly.
human neuroscience · SEEG · fMRI · sleep · coupling patterns · signal readout · Fourier phase · reproducible analysis
References
15- usesGroup mean signed correlation rose from wake to N3 in 56 SEEG patients and fell in 16 fMRI participants sci:sha256:2f6125d4d7d1b3f801e27e01f8fe61e1f3db5268bccba5da8a7f3fa33cc11d17
We adapt its source download, reader and signal utility code. We test residual pattern retention.
- usesN3 cortical lag products exceeded a reversible Gaussian spectral control in 43 SEEG patients and 16 fMRI records sci:sha256:01ad3c9e17137bd136021f1c390277d47011055663cfcf76981319cfd7711e78
We adapt its continuous segment and fMRI run reader logic.
- usesWake-to-N3 coupling scores passed primary tests in 34 SEEG patients and eight fMRI participants but not SEEG spectrum and gap checks sci:sha256:6a5d54674073cd1bb6cf878d9ef6543dea818b4029b02d94f4cd45d77cee2a5b
Its spectrum limit motivated our equal-power check before new human outcomes. Our score tests retention rather than state change.
- doi:10.1073/pnas.1111133109
- doi:10.1523/JNEUROSCI.0217-18.2018
- doi:10.1523/JNEUROSCI.1845-24.2025
- doi:10.1093/brain/awy035
- doi:10.1002/ana.25304
- doi:10.1002/ana.25651
- doi:10.82901/nemar.nm000362
- doi:10.5281/zenodo.16755776
- doi:10.1016/j.neuroimage.2012.06.036
- doi:10.1371/journal.pcbi.1012852
- doi:10.1006/nimg.2001.0978
- doi:10.1371/journal.pone.0068910
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesSleep map shape tests passed in 19 SEEG patients and 15 fMRI records under independent window errors
We adapt source readers, downloader and projection/Fourier helper structure. Its retained maps motivate a test of state change beyond scalar gain.