sciscape Publications
← All publications

Calibration across seven checks reduced before-pulse SEEG calls at 85 selected sites in eight people

We tested repeated reading of public SEEG voltage after stimulation. We used 85 selected sites in eight people from OpenNeuro ds004696 version 1.0.1. Five early pulses fixed each response template and its thresholds. Five later pulses per site supplied 425 after windows and 425 before windows. Seven separate thresholds increased the equal-person before-call rate from 13.98% at one final check to 46.90%. One shared threshold across seven checks reduced it to 17.45%. Relative to separate thresholds, the shared rule reduced after calls by 5.04 percentage points and added 69.62 ms to mean assigned after decision time. All three fixed sensitivity tests kept this tradeoff. Independent score and decision checks passed, and a full repeat gave identical output hashes. The package preserves voltage, code, figures, source checks, and all decisions. This offline result concerns selected pulse windows in reused sessions. It does not prove neural-response labels, a clinical rate guarantee, or a live BCI benefit.

stereoelectroencephalography · electrical stimulation · signal processing · brain-computer interface · calibration · threshold crossing

Admitted 0 citing publications

References

6
  1. usesCalibration across five reading times kept more true sites but gave fewer labels in five offline 6 mA SEEG sessions sci:sha256:ac8ec2ecea226c968608230f0c3bea607bccca4bb5de45ca8f9d4a5fcccfa565

    This study motivated calibration across reading times. It tested offline site labels in another SEEG dataset. We measured binary pulse-window calls and assigned time in ds004696.

  2. usesSixty block means gave the same SEEG detection AUC as 960 samples on five later pulses at each of 85 selected sites in eight people sci:sha256:405201883414d702109e92cb19e43990240ed9b4363fe499c84941c63d980f8e

    This publication supplied the exact selected voltage, pulse tables, source hashes, and exclusion of sub-08 site 0. We kept all 983 native samples and tested seven prefix checks instead of waveform compression.

  3. usesPast pulse updates reduced normalized 20–500 ms SEEG forecast error versus fixed five-pulse templates at 86 selected sites in eight epilepsy sessions sci:sha256:fd07147e53abc31f50ad87cee1d777a9d91b45b3d2a172703485899005f00530

    We used the adapted range download code to retrieve complete pinned MATLAB files one at a time and check every saved waveform.

  4. usesSingle-pulse F limits covered 68.5 percent of five-pulse SEEG sequences after five fit pulses at 86 selected sites in eight patients sci:sha256:4a65d215e06b8a5c193d7ce1ff05f57db9c55f5165190050bb397d50489772fc

    We used its extraction metadata and source verification recipe through the input chain. They map saved pulse voltage to original contact and event rows.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis used processed voltage and event information from OpenNeuro ds004696 version 1.0.1.

  6. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

0 publications