One added 400 ms pulse gives a test that cancels baseline error in human ECoG and fMRI designs under a stationary pair model
We studied a visual timing design shared by separate human ECoG and fMRI studies. An exact calculation shows that all twelve active conditions can fit an arbitrary stationary signed pair-interaction model if the response baseline is free. The design has rank twelve. Adding one 400 ms single-image condition leaves rank twelve among thirteen means. Its unique test contrast cancels a common baseline. Thus one added condition is sufficient and necessary for this active-only scalar test under the stated model. A continuous signed kernel can realize the finite pair coefficients. Interpolation matched all active means at 94 ECoG contacts and 48 fMRI region records. These exact fits are a design limit, not model validation. An initial fixed negative-direction test of an earlier identity failed in five reserved ECoG patients and six fMRI adults under all 72 possible repeated-person links. Shared p was 1.0. All controls and two failed exploratory monotonicity tests remain. The new assay can miss higher-order terms that cancel. Finite tails and nonlinear measurement can also break its neural meaning. Noise factors are conditional and do not show a power gain for a common effect. The added pulse was not measured. No new positive shared neural finding is claimed. Code, permitted inputs, source pins and terms, plans, all results, figures, an assay tool, and repeat steps are supplied.
visual cortex · temporal summation · ECoG · fMRI · identifiability · baseline · experimental design · quadratic model
References
6- usesA temporal interaction test did not show a shared violation in eight ECoG patients and six fMRI adults sci:sha256:7c356923470735652f38a6554d2f9153b5c41a85fc1dd2902d5bb9a18733b551
We reproduce its five-response identity and build on its baseline limit. The full-design rank certificate and added-condition test extend that work.
- usesA duration response rule did not pass a shared prediction test in five ECoG patients and six fMRI adults sci:sha256:a10936a6971e0c27462a0bba2bc732c2339d769c78c9b0c1a645261566201365
We reuse verified compact electrical inputs, the original fMRI file, source readers, source pins and the electrical split.
- usesdoi:10.18112/openneuro.ds004194.v3.0.0
Public CC0 author-processed electrical epochs and metadata supply the ECoG response summaries.
- usesdoi:10.1523/JNEUROSCI.1812-21.2022
The original human ECoG study defines the source task and processing.
- usesdoi:10.1523/JNEUROSCI.1724-17.2017
The original human fMRI study and OSF v843t file wn2q9 version 1 supply condition response estimates under CC BY 4.0.
- doi:10.1016/j.mbs.2009.11.010
Prior paired-pulse quadratic system identification.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesAt stated errors and fixed pulse plateaus, 90% recovery time had no upper bound in three ECoG and two fMRI records under a positive-mixture model
We reuse its verified compact public inputs, source readers and source-rebuild code, with preserved notices.