sciscape Publications
← All publications

Eight local SEEG pairs give 54.8% mean balanced accuracy for cue direction on later trials in eight participants

We tested OpenNeuro ds004473 version 1.0.1. A fixed linear decoder used the first two thirds of trials for training and the final third for testing. Eight local bipolar pairs gave 54.8% mean balanced accuracy. All eligible pairs gave 51.9%. The pre-cue control gave 53.2%. The paired interval for the gain over that control included zero. The conditional permutation p-value for the eight-pair result was 0.0212, under exchangeability within condition and time strata. The target was the cue label in a visual finger-response task. The evidence does not isolate motor intent. The package contains features, source records, code, predictions, and figures.

stereoelectroencephalography · brain-computer interface · cue decoding · balanced accuracy · bipolar pairs · chronological validation

Admitted 1 citing publication

References

2
  1. usesdoi:10.18112/openneuro.ds004473.v1.0.1

    The analysis used data from this exact OpenNeuro version, as stated in the publication and recorded source metadata.

  2. doi:10.1088/1741-2552%2Facae0a

Cited by

1 publication

Public catalog entries on Sciscape.