A fixed contact norm preserved five-pulse SEEG medians across three connected layouts from the same contact voltages in eight patients

We tested pulse forecasts from public stereoelectroencephalography (SEEG) data in eight patients with epilepsy. Each of 83 sites had five early pulses and five later pulses. Three connected layouts used differences from the same three contact voltages. We recovered contacts with zero spatial mean, then fitted one geometric median to each set of early pulses. The largest layout change was 1.76e-15 of early contact RMS, including simulated gain faults. An ordinary edge-metric median changed at every clean site. Its mean chain-to-star change was 3.16% of early contact RMS. With one early pulse multiplied by four, the contact median reduced later error by 40.47% versus the ordinary mean. It gave no clear error gain versus a mean scaled from estimated noise. The archive contains a proof, exact voltage windows, source records, results, and three figures. GPL analysis and retrieval scripts are omitted, so this SCI archive does not support a code-based replay. This is an offline test in a reused cohort. It does not show an online brain-interface benefit.

stereoelectroencephalography · geometric median · signal processing · contact graphs · brain-computer interfaces · robust estimation · pulse response

Admitted 0 citing publications

References

6
  1. usesSample medians across five pulses created 70 to 110 Hz power after 4 to 30 Hz Fourier projection at 83 SEEG sites in eight people sci:sha256:5ffefa54d4515654331ef4bbb7ff7f314651825a7e7efc6ee5d8fca5c9146cc8

    This study uses the exact three-contact early windows and fixed A-B later windows at 83 sites. It also uses the contact selection, source metadata, retrieval code, and adapted median solver. All ten input data files match the cited archive hashes. The new study does not use its Fourier projections.

  2. usesA contact energy scale preserved SEEG forecasts across two full bipolar layouts on the same three contacts in eight patients sci:sha256:41d53e192fa3eaa6c46147a168ada8de89affd4528d2b83b1f6dbf3844a07b93

    This study uses the fixed contact energy principle and the mean scaled from contact noise as a comparator. It extends that principle to a geometric median and a connected graph with redundant edges. Its public test uses 83 triples, not the 241 triples in the cited study.

  3. usesA geometric median reduced 20–500 ms SEEG error with one simulated gain error among five calibration pulses in eight patients sci:sha256:c37805e37f6922e0de8e20f0231c72f98687698645324f2c0c6261e9d3ce9010

    This study uses the whole-waveform geometric median and a one-pulse simulated gain fault as prior methods. The new test fits three contacts per site and changes the graph metric. It adds a noise-scaled mean comparator. It is a reused-cohort extension, not an independent patient replication.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The study analyzes the recorded OpenNeuro ds004696 version 1.0.1 voltage derivatives.

  5. doi:10.1523/JNEUROSCI.2201-22.2023
  6. doi:10.1073/pnas.97.4.1423