A fixed pulse limit increased detection of imposed SEEG gain trends in eight recordings under an exchangeable pulse model
We tested a sequential rank alarm on public SEEG responses from eight people with epilepsy. The data contained 85 sites, 879 bipolar readouts, and 987 pulses. The primary alarm used two pilot pulses, stake 0.5, and threshold 20. We proved that it needs at least 13 total pulses. It could not fire at 69 sites within the recorded count. In paired software tests, it detected a gradual 50% recording gain decrease in 0.65% of trials. A secondary rule set its threshold for a fixed pulse limit with 65,535 null rank paths. It detected the same decrease in 41.08% of trials, with a descriptive person bootstrap interval from 30.81% to 51.24%. Its unchanged-gain reference alarm rate was 5.06%. The error proof requires pulse exchangeability conditional on the pilot and fixed readouts. The fixed limit must be declared before monitoring. Recorded changes had no validated labels. Constant positive gain left the ranks unchanged. The local historical archive preserves code; this SCI package preserves compact data, five figures, source hashes, all results, and retrieval instructions. A fresh full-source check for one person reproduced every matrix and table exactly.
sequential rank test · exchangeability · change detection · stereoelectroencephalography · pulse limit · signal monitoring
References
6- usesAt rate 1, learned weights reduced 20 to 500 ms SEEG forecast error against equal weights but raised error against scaled means in eight recordings sci:sha256:ef0c0959114fb72eaef63b2306de27883d737af4882e1642fc43cc265cd97c7b
We used its GPL bipolar extraction helper through the direct source publication. It supplies the window definitions, contact mapping, and source event selection.
- usesOffline response noise allocation had an uncertain 20 to 500 ms centered bipolar SEEG forecast gain at three pulses per site in eight recordings sci:sha256:db1783f4ac7c0e423bcd3a5e4b0490e6bf59a9201b52f2cb337c73f192cffa26
We used its all-pulse Gram matrices, event and site tables, direct voltage example, source records, and retrieval helpers. The new question concerns sequential rank alarms and their pulse-count limit.
- usesA flexible calibration rule reduced 20 to 500 ms SEEG forecast error against concentrated calibration at the same budget in eight recordings sci:sha256:b11e64a72d90d5d9472330f22107d3989f0a6dcd64b08dca4eef577da0e4478b
We used the all-pulse extraction and retrieval lineage preserved by the direct source publication. It supplies the compact matrix schema and pinned processed-source receipts.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analyzed processed SEEG response data and retained compact numerical inputs are from this dataset version.
- doi:10.1523/JNEUROSCI.2201-22.2023
- doi:10.1093/biomet%2Fasae023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.