Five early pulses selected map ranks that reduced mean centered 20–500 ms SEEG error versus rank 1 in eight STReEF patients
We tested whether five early pulses could choose the size of a SEEG response map for five later pulses. The source was OpenNeuro STReEF ds005448 version 1.0.0. The sample had eight patients, 96 conditions, and 6,803 recording-pair rows across conditions. The later group reversed the recorded contact order. Early leave-one-out validation chose among ranks 0, 1, 2, 4, 8, 16, and full. The map was then refitted on all five early pulses. No later voltage entered choice or fit. In the strict 20–500 ms window, selected ranks reduced later centered-voltage squared error by an equal patient mean of 4.65% versus fixed rank 1. The descriptive 95% patient bootstrap interval was 2.17% to 7.00%. Seven patients improved. The exact patient sign-flip reference was p = 0.015625 under an independent, sign-symmetric null. The rule chose zero in 46 conditions. Its gain versus zero was uncertain. The before-pulse control also improved versus rank 1. Thus lower error does not identify a neural source or prove effective brain writing. Time and contact order are confounded. Eligibility uses annotations for both groups. This is an exploratory study on a reused sample. The package preserves code, source metadata, pinned retrieval records, fold terms, native examples, tables, and four figures. All 960 fresh voltage ranges matched their source hashes. All 2,688 later candidate errors matched the parent analysis. All five result files reproduced exactly.
SEEG · intracranial EEG · response map · rank selection · calibration · voltage prediction · singular value decomposition · brain-computer interfaces
References
4- usesOne component reduced mean 20–500 ms SEEG forecast error in eight STReEF patients with five fit pulses sci:sha256:70cb3f34adb0cf7f82202c7ad84ada2673221b74d7b20e7c4e61303bcec26793
This publication supplied the fixed 96-condition sample, source metadata, pinned byte-range receipts, recovery code, native audit examples, and fixed-rank error references. We retrieved all selected voltage ranges again, added early validation folds and rank choice, and checked all 2,688 later candidate errors against its results.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
Source dataset used: STReEF, OpenNeuro ds005448 version 1.0.0, including SEEG voltage and metadata.
- usesdoi:10.1016/j.ynirp.2025.100274
Source study for STReEF data provenance and study context.
- doi:10.1007/s12021-022-09567-6
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA scaled shared waveform had higher 4–30 Hz SEEG forecast error than a scaled full map at 100–500 ms after pulses in eight patients
This publication supplies context for early response-map rank calibration in a separate SEEG cohort. It helped define the new comparison with a full map under matched amplitude calibration. No numerical data or fitted model from that publication enters this study.