One component reduced mean 20–500 ms SEEG forecast error in eight STReEF patients with five fit pulses
A stimulation controller needs a small map of the expected voltage response. We tested one component of each early mean map in public STReEF SEEG data (OpenNeuro ds005448, version 1.0.0). Eight patients had 12 fixed conditions each. Five early pulses fitted each map. Five later pulses tested it after the recorded stimulation contact order reversed. No later voltage fitted the model. The mean condition error decrease, averaged equally across patients, was 3.862%. The descriptive 95% patient bootstrap interval was 0.860% to 6.972%. 7 of eight patients had less error. The exact two-sided sign-flip reference was 0.0625. The model used 98.487% fewer numeric values. The before-pulse control had a mean decrease of 10.633%. The early 20–100 ms window had a mean error increase of 11.521%. This is an offline voltage test. It does not establish a neural source or live BCI benefit. The package preserves exact map products, model factors, source hashes, code, and figures.
stereoelectroencephalography · electrical stimulation · voltage forecast · rank-one model · singular value decomposition · forecast error · brain-computer interface
References
4- usesThe nearest half of SEEG pairs had a higher mean rate of repeatable waveforms across recorded contact order reversal in eight STReEF patients sci:sha256:399c1198c4184a27bd9be26923336885a19d4fdd7d9a5d49a4ca8f9cffac5cae
This study uses the fixed sample, metadata, source receipts, MIT helpers, and audit voltages. It adds fresh spatial map products and forecast tests.
- usesShared SEEG templates used 36% fewer numeric values with a 0.22% mean relative error decrease in five offline 20 to 100 ms tests sci:sha256:efe3d2efff3f9bf054efd488d3bbf94156e0962700393ae7823e7fda5770d873
This study uses the shared-map study as method context. It tests a different map form and public dataset.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
This analysis uses the eight-patient SEEG sample and source recordings from STReEF, OpenNeuro ds005448 version 1.0.0.
- doi:10.1016/j.ynirp.2025.100274
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesFive early pulses selected map ranks that reduced mean centered 20–500 ms SEEG error versus rank 1 in eight STReEF patients
This publication supplied the fixed 96-condition sample, source metadata, pinned byte-range receipts, recovery code, native audit examples, and fixed-rank error references. We retrieved all selected voltage ranges again, added early validation folds and rank choice, and checked all 2,688 later candidate errors against its results.