Four learned patterns had 2.34 percent higher mean relative error than four cosine patterns in five SEEG patients with separate shafts
We tested whether learned time patterns improve prediction of a five pulse SEEG mean. SEEG means stereoelectroencephalography. We used OpenNeuro ds004457 version 1.0.2 and five patients. We learned patterns from other stimulation shafts in each patient. The fixed main model used four patterns. The comparator used four fixed cosine patterns. The test used 1081 selected links, 50 to 250 ms, and all 252 complementary five pulse groups. The mean patient error reduction was -2.34 percent. The descriptive patient resample limits were -10.50 to 3.87 percent. The conditional two sided sign flip p value was 0.6875. Two patients improved. The two pattern model had a mean 7.70 percent reduction. The eight pattern model had a mean 3.29 percent increase. An exact finite pool calculation separated observed mean loss from pulse split variation. The package contains source locks, pulse data, learned patterns, all results, and independent checks. A fresh raw rebuild matched every saved waveform value. These results apply to the selected pulse pool in known patients.
stereoelectroencephalography · electrical brain stimulation · evoked response · principal component analysis · pulse prediction · finite pool loss · OpenNeuro
References
5- usesSquared voltage centre times preserved late SEEG site order better than absolute peak times in five patients with separate smoothed five pulse means sci:sha256:f0c96714c1ac9c03c65e7ef2118867dd2e9b1c2ab71ee2c8b2d6410c9bc734b5
The inherited extraction code and receiver selection came through this publication.
- usesA variance rule reduced average 50 to 250 ms SEEG prediction error in five patients with separate five pulse groups sci:sha256:335cdede136528c2246142ff023095aeaebe4b09b0b78a45abc1cd9dc2cc0387
The study uses its pulse arrays, source metadata, source locks, and variance rule as a fixed comparator.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analysis uses recordings and metadata from OpenNeuro ds004457 version 1.0.2.
- doi:10.1523/JNEUROSCI.1325-22.2023
- doi:10.1371/journal.pcbi.1011105
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesPulse variance correction reduced three component 50 to 250 ms SEEG prediction error in two of five patients with separate stimulation shafts
Its separate shaft analysis motivated equal training site weights and the exclusion of target stimulation shafts. Its finite pool loss decomposition informed the algebraic audit and interpretation. The new study adds fixed pulse covariance subtraction and a matched raw basis.