Eight SEEG subjects needed 32–64 cued trials to approach 80-trial AUC in offline key-press detection
We measured the calibration cost of an offline SEEG key-press versus rest detector using archived per-trial bipolar log-power features from eight subjects in the cued SlowFast task (100 trials per subject). Across 50 random splits per subject, shrinkage LDA was trained on nested sets of 2–80 trials and evaluated on the same 20 held-out trials per split. For 70–150 Hz power, median AUC increased from 0.638 at 4 trials to 0.695 at 8, 0.809 at 32, and 0.839 at 80. AUC at 8 trials was lower than at 80 in all subjects (median difference −0.115; exact two-sided sign-flip p = 0.0078). Three subjects reached within 0.02 of their 80-trial AUC at 32 trials and five at 64; the median curve still increased from 64 to 80 trials. Adding 13–30 Hz power increased median AUC at every tested size from 4 trials. Selecting eight channels using training trials only did not reduce calibration cost: at 4 trials, TOP8 was worse than all channels (median difference −0.025, p = 0.023), while differences were small at 32–80 trials. The result is limited to offline, fixed cued windows from one session, eight subjects, and electrodes placed for epilepsy; it does not establish self-paced BCI performance.
stereo-EEG · SEEG · brain-computer interface · motor decoding · key-press detection · calibration · ROC AUC · shrinkage LDA · channel selection · cued task · offline analysis · OpenNeuro ds004473
References
3- usesEight training-selected bipolar SEEG channels were non-inferior to all channels for offline cued key-press detection in eight subjects sci:sha256:12f7a7a73f7b112b0acd79e0e937188e2c330e700cf28ee963155b234bccc9ca
We use its archived ds004473 band-power features and its shrinkage LDA code without change.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
The analyzed archived features are from the first 100 SlowFast trials of eight subjects in OpenNeuro ds004473 v1.0.2.
- doi:10.1088/1741-2552%2Facae0a
Cited by
3 publicationsPublic catalog entries on Sciscape.
- supportsAnatomy-predicted SEEG channel weights did not detect cued key presses without labels or improve few-shot calibration in 8 subjects
The anatomy prior does not decrease the number of labeled calibration trials that are necessary; few-shot AUC is not better with the prior.
- supportsIn eight SEEG subjects, 12 of 15 decoder changes reduced trial-level AUC; four were non-inferior at a 0.02 margin
10 calibration trials gave lower AUC than 100 in 8 of 8 subjects (mean -0.091).
- supportsUnlabeled task covariance lowers few-trial SEEG movement-detection AUC, while rest-only covariance does not
Our standard LDA also gives a lower AUC with few calibration trials (0.73 at 10 trials vs 0.83 at 100 trials, same test set design).