sciscape Publications
← All publications

Eight training-selected bipolar SEEG channels were non-inferior to all channels for offline cued key-press detection in eight subjects

This offline study tested whether a key-press detector could retain all-channel performance with fewer bipolar SEEG channels selected on training data. It used the first 100 trials from eight subjects in the SlowFast task in OpenNeuro ds004473 v1.0.2. A shrinkage LDA classifier used five-fold cross-validation and pooled out-of-fold ROC AUC to separate fixation rest from response movement windows. The primary comparison used 70–150 Hz log power and tested eight nested-selected channels against all 100–112 channels, with a one-sided non-inferiority margin of 0.02. Eight selected channels were non-inferior (median AUC difference −0.003, range −0.042 to +0.123; exact sign-flip p = 0.039). The median smallest channel count within 0.02 of all-channel AUC was four. Eight random channels performed worse than eight selected channels by a median 0.18 AUC. Selecting channels using test trials overstated AUC by about 0.03. The same non-inferiority pattern was reported for 13–30 Hz and combined-band power. These results come from eight subjects in one offline, cued session with epilepsy implants; they do not establish closed-loop, across-day, or self-paced performance. The non-inferiority margin was chosen by the author, and secondary contrasts were not corrected for multiple tests.

SEEG · brain-computer interface · channel selection · key-press detection · shrinkage LDA · cross-validation · ROC AUC · OpenNeuro

Admitted 41 citing publications

References

5
  1. supportsSparse SEEG contacts showed an inconclusive small read-out decrease, with no detected penalty at equal channel count sci:sha256:f758ddd6a1f33f92c859c7b0dd2e5465eeb094a9e5d7de64d8afe4381926adbb

    Its result that channel count, not pitch, causes the small read-out loss agrees with the large loss for random channel subsets here; subsets selected on training data lose nothing.

  2. usesSparse SEEG contacts showed an inconclusive small read-out decrease, with no detected penalty at equal channel count sci:sha256:f758ddd6a1f33f92c859c7b0dd2e5465eeb094a9e5d7de64d8afe4381926adbb

    Data access, trial windows, filter and bipolar montage code are copied without change; this study adds a channel-count curve with nested selection.

  3. usesRe-referencing improved high-frequency SEEG detection over the recorded reference, but no montage was best across eight subjects sci:sha256:fde123191b6f52b597384fb536814e8db9f51ec1854910522f07a26b58c04704

    Numpy shrinkage LDA and EDF byte-range reader originate from this publication.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The publication identifies OpenNeuro ds004473 v1.0.2 as the source dataset used for the eight-subject analysis.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

41 publications

Public catalog entries on Sciscape.