sciscape Publications
← All publications

At a 16:9 field scale, two coordinate rules gave no clear added visual axis alignment term for connections among 3,437 neurons in one MICrONS mouse

We tested whether recorded excitatory links align with a target neuron's preferred visual bar axis in one MICrONS mouse. The main panel had 3,437 neurons, 1,905,276 candidate directions and 20,421 recorded links. A fixed linear model controlled source identity, target and local source groups, and geometry. At a planar field scale of 16:9, the adjusted along-axis minus across-axis contrast was -0.085 percentage points under a top-left origin. It was -0.071 points under a bottom-left origin. The two planned tests had Holm-adjusted normal-reference p values of 0.064 and 0.075. An added leverage correction gave pointwise 95% ranges of -0.209 to +0.039 and -0.197 to +0.055 points. All eleven planned scope checks gave negative point estimates. These results give no clear added alignment term in this model. They do not establish zero effect or the absence of contour integration. Official data sources give opposite vertical coordinate rules. All 8,284 matched field centers agree with the current v2 export, so we tested both rules. A new scan of all 303,164,967 original connection rows recovered the complete reused matched graph. The package preserves that graph, the candidate panel, code, source hashes, all results, figures and repeat steps. Limits include one mouse, model field centers, assumed planar geometry, incomplete axons and approximate conditional uncertainty.

MICrONS · connectome · visual cortex · orientation · contour integration · field center · coordinate convention · neuron fixed effects · dyadic covariance · structure and function

Admitted 0 citing publications

References

9
  1. usesA fixed test of 546 MICrONS connections gave no clear mean synapse size relation to motion direction after orientation and neuron controls sci:sha256:0880b422c86f2f45dad497f8822c9cd8cefb417131f395827eafcc59792cb194

    We reuse its complete matched graph and extraction code. A new full source scan recovered every selected neuron and link.

  2. usesAt two recorded synapses per pair, two-way links gave no clear decrease in model field center distance in one MICrONS mouse sci:sha256:8e43e6d2acc38f14d834bfeb1f227f87595e1c5d5b09a1b7861991f2b86927e2

    We use its verified matched graph copy and source provenance. The present test concerns visual axis alignment rather than reciprocal field-center distance.

  3. usesdoi:10.1038/s41586-025-08790-w

    The MICrONS structural and functional data come from this mouse volume.

  4. usesdoi:10.1038/s41586-025-08840-3

    This work supplies functional-connectomics methods and orientation estimates for the exported model.

  5. usesdoi:10.1038/s41586-025-08829-y

    We use exported field centers and tuning properties from this neural response model.

  6. doi:10.1038/s41586-026-10457-z

    This correction clarifies the description of the neural response model. We use exported properties and do not retrain it.

  7. usesdoi:10.1038/s41586-024-07765-7

    The matched extract uses MICrONS cell labels based on the associated cell-class resource.

  8. doi:10.1038/nature23019

    The spine input study motivates a visual axis alignment test. Our scalar field-center and recorded-link test is narrower.

  9. doi:10.1038/s41586-020-2894-4

    The spatial input study motivates the relation between target tuning and input location. Our large-volume test uses different measurements.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.