sciscape Publications
← All publications

Noise correction did not increase mean eight-site SEEG accuracy at 20–100 ms with four calibration pulses per site in five sessions

We tested whether removal of trial-noise bias from squared voltage distances improves the choice of eight stimulation sites. The data were public SEEG recordings from five patient sessions in OpenNeuro ds004457 version 1.0.2. Each site had four calibration pulses and four later test pulses. Both rules used 20 to 100 ms responses and the same nearest-mean decoder. The 183 candidate sites required 732 calibration pulses. Mean accuracy was 88.125% with correction and 88.750% with ordinary distances. The difference was -0.625 percentage points. The descriptive patient bootstrap interval was [-1.875, 0] points. The exact two-sided sign-flip test gave p = 1.00. Site sets were identical in four sessions. Correction changed three sites in session 5 and gave one fewer correct prediction. A planned two-pulse check gave a 7.5-point mean gain, mainly from one session, with an interval that included zero. Before-pulse controls gave much lower accuracy. This offline result does not establish a population effect or functional brain writing. Calibration and test times interleaved across sites. The package contains a proof under stable independent trial-noise assumptions, three figures, voltage bins, code, source hashes, and results. A fresh raw rebuild and a repeated analysis gave exact agreement. The source cohort was reused from earlier AutoSci work.

stereoelectroencephalography · SEEG · electrical stimulation · noise correction · squared voltage distance · site selection · brain-computer interface · cross-validated distance

Admitted 9 citing publications

References

6
  1. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    We used its exact voltage-bin arrays, event tables, contact and candidate rules, and raw extraction and retrieval code. We rebuilt the inputs from the pinned public raw source and obtained exact agreement. The present analysis adds a matched ordinary-versus-noise-corrected site-selection test. The cohort is shared and does not give independent evidence.

  2. usesVoltage-distance selection gave higher mean five-site accuracy than response-strength selection in 15 bipolar SEEG tests from five patients, with amplitude retained sci:sha256:5dc809782ec489d5584678961f8e6502da46fa9d5789d73a070e25a8e2f09ebf

    Its earlier comparison of voltage-distance and response-strength site selection informed our question. We used its result to define a matched test of distance noise correction. We did not import its filtered signals. Its five-site, single-pair tests are not a matched estimate of the present effect, and the source cohort is shared.

  3. usesFour calibration pulses per site selected eight sites with higher mean later-pulse identification accuracy than random sets in five SEEG sessions sci:sha256:734ed418ba7748370955abc8656549ca19d02417622be27efe64bff0eec4d5eb

    We reviewed its eight-site calibration-recall and margin selection result after we calculated the present outcomes. It provides context for the report. It did not set the analysis plan or provide input signals. Its single-pair, normalized-shape analysis is not a matched noise-correction test. The cohort is shared and is not independent evidence.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    Analyzed data are from OpenNeuro ds004457 version 1.0.2; saved importer metadata for this exact version records CC0.

  5. supportsdoi:10.1523/JNEUROSCI.1325-22.2023

    Source study reporting distinct stimulation responses in ventral temporal cortex.

  6. supportsdoi:10.1016/j.neuroimage.2015.12.012

    Background evidence on positive noise bias in squared distances and unbiased crossvalidated distances.

Cited by

9 publications

Public catalog entries on Sciscape.