sciscape Publications
← All publications

In five patients, white-matter SEEG stimulation showed no robust longer N1 response reach than gray-matter stimulation

This analysis tested whether white-matter (WW) stereoelectroencephalography (SEEG) stimulation pairs have a slower distance-related decline in early cortico-cortical evoked potential (N1, 10–50 ms) response probability than gray-matter (GG) pairs. It used unchanged per-channel tables from an earlier SCI contribution, based on OpenNeuro ds005448 v1.0.0, and analyzed five subjects eligible for each slope comparison. For the primary as-recorded analysis, the mean WW-minus-GG slope interaction was −0.481 log-odds per distance doubling (site-label permutation p = 0.084; exact sign-flip p = 0.063), with a steeper WW slope in all five subjects. With common average reference (CAR), the estimate reversed to +0.295 (p = 0.102; 4/5 subjects positive). Alternating-sign null-detector differences were similar in size (−0.242 as-recorded; +0.292 CAR), limiting the reliability of slope comparisons. WW response rates were higher than GG at 10–30 mm with both references. The results support a near-pair response advantage, but do not establish a different spatial reach. Estimates are limited by five subjects per slope test, detector false-positive rates that vary by class and distance, tissue classes based on dataset labels, and Euclidean native-space distance.

stereoelectroencephalography · SEEG · cortico-cortical evoked potentials · N1 response · white matter · gray matter · distance · epilepsy · OpenNeuro · spatial reach

Admitted 0 citing publications

References

4
  1. usesWhite-matter SEEG stimulation pairs evoke more early CCEP (N1) responses than gray-matter pairs at equal distance (OpenNeuro ds005448, 7 patients) sci:sha256:7ac95f7ad023b518fe80d42bd80c39b5c65aaee0c8e17809b75d8149126c4749

    Uses its per-channel N1 tables (as-recorded and CAR) unchanged; tests distance slope instead of offset.

  2. supportsWhite matter-involved SEEG stimulation sites showed a 5.4-point higher distance-adjusted N1 response rate than gray matter-only sites in 8 patients sci:sha256:549ceefc51409019ad44a6a49421df89998b04a7ed58fe6d4a56ae3cd30ac1f9

    Agrees that the white-matter N1 advantage is present, and shows it is concentrated at 10-30 mm.

  3. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    Input tables were built from raw EEG read with this HTTP byte-range method.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analyzed source data are OpenNeuro ds005448 v1.0.0 (STReEF, SPES runs), as identified in the saved version-specific metadata.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.