Five early waveforms retained 61.2 percent of later SEEG energy with measured later coefficients in eight patient sessions
We tested a five-waveform representation bound for public SEEG in eight epilepsy patient sessions. The data were OpenNeuro ds004696 version 1.0.1. The test used 86 sites and 886 stimulation-to-readout pairs. Five early pulses defined each space. The final five pulses tested it. The 20 to 500 ms space retained 61.2 percent of later energy. A separate before-pulse space retained 48.9 percent. Both windows had 983 samples. Energies used early after-pulse normalization, with equal site and patient weights. The difference was 12.33 percentage points and was positive in all eight patients. The descriptive patient bootstrap interval was 9.65 to 15.34 points. However, the space retained only 47.4 percent of later after-pulse variation. Extra directions also retained background energy. Each projection coefficient used measured later voltage. Thus the result gives an optimistic representation bound, not a forecast available before stimulation. Independent SVD and event audits passed. Source-file hash records came from the prior extraction. The package preserves exact trial products, code, three figures, a reusable scoring tool, provenance, and reproduction instructions.
SEEG · stereoelectroencephalography · waveform representation · brain-computer interface · electrical stimulation · representation bound · principal components · OpenNeuro
References
6- usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f
Exact input matrices, display means, contact selection, event selection, source metadata, retrieval code, and raw-file audit records.
- usesFour donor components increased mean squared voltage error 6.58% versus noise scaling after five calibration pulses in eight SEEG sessions sci:sha256:e07992604353bd543813f27b0fe25ba60bb5ac2fae9450d1858f5e063bb20936
Prior shared donor-component forecast test motivated a bound for a local early space; its data and numerical scores are not inputs.
- usesIdeal signed scale changes left 84.5 percent of 20–500 ms SEEG error for a fixed five-pulse waveform in eight patient sessions sci:sha256:c1013f1f75ee1d942a3ee7287ce6ea0c2a5f9632b77790eb3acd7cd28e98b3b6
Prior ideal signed-scale bound motivated extension from the early mean direction to five early waveform directions.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis uses preserved trial products derived from OpenNeuro ds004696 version 1.0.1; the source release metadata records this version-specific DOI and CC0 license.
- doi:10.1523/JNEUROSCI.2201-22.2023
- usesdoi:10.1371/journal.pcbi.1011105
The source files are CRP derivatives; this publication analyzes their single-trial arrays and does not use CRP fits or significance results to select readouts.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesThe test did not detect a positive time relation for SEEG waveform distance at 20 to 500 ms in eight sessions under log count control and joint pulse exchangeability
We used its exact ten-pulse Gram products, contact tables, and source metadata to test elapsed time and good-pulse count.