Fixed SEEG ranges showed no clear increase in excess same-side misses across shafts at 20–500 ms after pulses in eight people
We tested whether fixed SEEG size ranges missed together on different recording shafts. We used public OpenNeuro ds004696 version 1.0.1. The test retained 83 stimulation sites in eight people and five late pulses per site. The excess of same-side misses was 0.66 percentage points in the 20–500 ms window and 0.18 points in the baseline window. The mean paired change was +0.48 points. A descriptive 95% person bootstrap interval was −0.31 to +1.70 points. The exact sign-flip reference value was 0.695. The result does not show a clear increase or establish that the change is zero. Omitting one person changed the mean to −0.08 points. The package adds an exact independent-shaft-order audit that keeps pairs on one shaft together. It preserves code, compact input data, pulse outcomes, fits, scores, three figures, source hashes, and repeat instructions. Fresh full-source extractions for two people matched every archived input field. The other six source checks are inherited. These data do not establish a neural cause or a live brain-computer interface benefit.
SEEG · intracranial EEG · electrical stimulation · brain-computer interface · response ranges · same-side misses · conformal prediction · exact reference · OpenNeuro
References
5- usesFive later pulses did not show higher SEEG size correlation across shafts at 20–500 ms than before stimulation in eight sessions with readouts selected from five early pulses sci:sha256:3e568cd9997feedb9652f1ade1733ba15c832a7040976086282aa09650536328
This earlier result supplies scientific context. It tested log size correlations across shafts in the same eight source sessions and did not show a clear increase after stimulation. The present audit tests failures of fixed ranges and uses all retained recording pairs in its main score. It uses no inputs or code from this earlier correlation package and is not an independent replication.
- usesJoint ranges for 20–500 ms SEEG size covered all retained pairs in 77.2 percent of later pulses on average across eight sessions sci:sha256:d9c7c1c9a0076a833425327e2ff6632ea883a25fbfa68b6a99d537b8e7124202
This study uses all 25 compact input files, the unchanged source extraction code, data instructions, and source provenance from this publication. It keeps the fixed range rule and selected pulses, then adds a cross-shaft miss alignment audit and a paired baseline comparison.
- supersedesFixed SEEG ranges showed no clear increase in excess same-side misses across shafts at 20–500 ms after pulses in eight people sci:sha256:400bea5e5415673b821747e2fa4e1d57ec2ad26dce750ddd20ab6ef39f45fdea
This version corrects the archive checker so that it excludes the metadata folder added by sci fetch. The first full archive retrieval exposed that problem. The data, analysis code, scores, and figures are unchanged. This version includes the correction and its retrieval check record.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analyzed compact inputs were derived from OpenNeuro ds004696 version 1.0.1; the source records identify this exact version and its CC0 license.
- usesdoi:10.1523/JNEUROSCI.2201-22.2023
The paper describes the OpenNeuro source recordings and provides provenance for the dataset used in this audit.