sciscape Publications
← All publications

At 16 sites, template noise subtraction reduced sound identity accuracy in six SEEG patients and 24 fMRI adults

We tested whether subtracting estimated template noise improves neural sound identity matching. Separate public studies supplied SEEG high-gamma responses and BOLD fMRI estimates. Development used two patients and four MRI adults. A local code lock preceded tests in six other patients, 16 B2021 adults and eight NH2015 adults. Each reader used ten 16-site panels. Training sounds set site scales. Two repeats supplied templates; the other repeat supplied queries. Full template noise subtraction reduced accuracy in all 30 reserved people. Mean changes were -5.791, -3.176 and -3.259 percentage points. Their 95% person Student intervals were [-7.000,-4.582], [-3.782,-2.570] and [-3.862,-2.656]. The fixed three-cohort intersection rule passed, p=0.015625. False choices favored templates with greater repeat disagreement. Fixed site, spatial and covariance checks kept negative mean changes. Short SEEG baseline subtraction greatly lowered both accuracies and reduced the loss to 0.667 points. Two B2021 adults improved with one-quarter correction. For one noiseless query, an exact independent-error model had correct expected distances but corrected accuracy 2^-K against K false candidates; ordinary accuracy was one. The model was not fitted to people. A second calculation reproduced every primary accuracy. Source audits checked all retained neural values. The package has code, source pins and terms, all outcomes, plans, figures and repeat steps. Original neural arrays remain external. Clinical sampling, source screens, separate cohorts, fixed sounds, repeat dependence and measurement filters limit scope. This is a shared reader-performance result. It does not establish a common neural code, noise source or cause.

human neuroscience · SEEG · fMRI · sound identification · template noise · crossvalidation · bias and variance · reproducibility

Admitted 1 citing publication

References

9
  1. usesUsing each template once improved sound matching in six SEEG patients and 24 fMRI adults sci:sha256:be4b3e9774764e7f5176e536ce06747d9f8c426549712c091f4173d9d3c3e0dc

    We reuse its verified public source preparation under MIT and build a distinct template correction test.

  2. supportsdoi:10.51628/001c.27664

    Prior theory established the bias and variance cost of unbiased distance estimation. Our decision test has a different endpoint.

  3. doi:10.7554/eLife.82566
  4. usesdoi:10.1371/journal.pbio.3001675

    Human SEEG source study.

  5. usesdoi:10.5281/zenodo.6544488

    Version v1.1 source data; exact Git and byte hashes supplied.

  6. usesdoi:10.1152/jn.00588.2020

    B2021 human fMRI source study.

  7. usesdoi:10.1016/j.neuron.2015.11.035

    NH2015 human fMRI source study.

  8. usesdoi:10.1371/journal.pbio.3002366

    Public author tar supplies the repeated fMRI arrays; exact neural archive hash supplied.

  9. doi:10.5281/zenodo.8349727

    Version-specific companion code archive and source metadata; this DOI does not pin the neural tar.