Mean FRandR count variance in 30-second windows exceeded a model with random five-second bin order in sleep SEEG from nine patients

We tested supplied FRandR marks in 153 five-minute sleep SEEG records from nine patients. FRandR is a fast ripple that overlaps a ripple. We proved an exact mean for count variance under random order of five-second bins. The mean patient ratio of observed to model variance was 1.314. Eight ratios were above one. The median was 1.074. Two patients accounted for 88.17 percent of the mean excess. None of 9,999 random draws reached the observed mean. The conditional one-sided simulation p value was 0.0001. A ten-second bin check gave a mean ratio of 1.167 and p = 0.0002. A shared order check gave p = 0.0002. The primary model assumes uniform bin orders within each record and independent permitted orders between records and patients. These results show time structure in supplied event counts under that model. They do not identify a neural cause or show clinical value. The package preserves 655 source files, hashes, new code, proof, count arrays, random draws, figures, checks, and repeat instructions.

high-frequency oscillations · SEEG · count variance · conditional randomization · temporal order · sleep · epilepsy

Admitted 0 citing publications

References

5
  1. usesFRandR counts in 5-second bins had a mean correlation of 0.069 between named shafts in nine sleep SEEG patients after removal of 30-second means sci:sha256:dc09e3b9ab20f503a8309120cd24d84716daf5530d0066b67d921cd877669be9

    Used its same-cohort count alignment study to state how the present variance question differs from alignment between named shafts. Its result arrays were not analysis inputs.

  2. usesFast ripple overlap exceeded the mean for uniform timing shifts in nine sleep SEEG patients sci:sha256:7c36b8354fa4d88cb48f475b606c8e19a201692a310a6b15ddd790f46af95a52

    Used its same-cohort interval overlap study as context for the FRandR event marks and to state the difference between interval overlap and count variance. Its result arrays were not analysis inputs.

  3. usesDispersed 30-second samples had lower FRandR rate error in five of nine sleep SEEG patients sci:sha256:5f37b3d8f7114cd339fa02ff6c40c1b53aaa0363b131a423d868aaf944892808

    Used its pinned source manifest, retrieval code, cohort rule, channel-set rule, and earlier count arrays as an independent validation reference. New counts were built from a fresh source download. The new test concerns count variance and temporal order.

  4. usesdoi:10.18112/openneuro.ds003498.v1.0.1

    The event and metadata tables used in the analysis were retrieved from OpenNeuro ds003498 version 1.0.1.

  5. doi:10.1038/s41598-017-13064-1

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.