Deep and superficial SEEG shaft halves had similar key-press AUC, but both scored below all pairs
In archived features from 8 subjects in OpenNeuro ds004473 v1.0.2, we compared offline key-press-versus-rest detection using deep (tip-side) and superficial (entry-side) bipolar pairs from stereoelectroencephalography (SEEG) shafts. We used contact number as a depth proxy, split each eligible shaft into equal-count halves, and trained Ledoit-Wolf shrinkage linear discriminant analysis (LDA) on log mean 70–150 Hz high-gamma (HG) and 13–30 Hz beta power. Training used trials 1–100; testing used trials 101 onward (32–198 test trials per subject). The primary mean test-AUC difference (superficial minus deep) was −0.004 (4/8 subjects positive; exact two-sided sign-flip p = 0.81; subject-bootstrap 95% CI [−0.036, 0.023]). Superficial and deep halves each scored below all pairs: superficial minus all was −0.038 (0/8 positive; p = 0.008; 95% CI [−0.059, −0.019]) and deep minus all was −0.034 (1/8 positive; p = 0.016; 95% CI [−0.047, −0.019]). The superficial half did not meet the planned 0.02 AUC non-inferiority margin against all pairs. With HG only, superficial minus deep was −0.034 (4/8 positive; p = 0.32; 95% CI [−0.091, 0.022]), and superficial minus all was −0.071 (1/8 positive; p = 0.039; 95% CI [−0.121, −0.022]). Single-pair HG AUC across five normalized shaft-position bins ranged from 0.525 at the tip to 0.536 in the middle bin and 0.534 near entry (831 pairs). These offline results in 8 clinical epilepsy subjects do not show a difference between the two shaft halves. The half-versus-all loss is confounded by the smaller number of pairs; equal-size random halves were not tested. Contact number is not anatomy, few pairs were near motor cortex, and subject 11 had only 32 test trials.
stereoelectroencephalography · brain-computer interface · key-press detection · linear discriminant analysis · high-gamma power · depth · AUC
References
1- usesBeta power increased later-trial SEEG key-press AUC in 6 of 8 subjects sci:sha256:b76113878b22b13b8fce6b4b57cf321bb22ce16b618b55ae02c2ef42b972f816
We use the archived ds004473 band-power features of this publication as the input.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesSeven-patient SEEG replication found no clear depth effect on movement decoding, but could not establish equivalence
We use the design and the LDA, AUC and test code of this publication and repeat its deep vs superficial test in ds006253. The result does not show a difference, but it does not meet our equivalence rule. Thus it is an inconclusive replication, not a full reproduction.
- supportsOuter and inner SEEG shaft halves showed similar movement detection in 15 patients, without evidence of equivalence
Same question (superficial vs deep shaft halves, shrinkage LDA, contact 1 assumed deepest) in a second dataset and task (ds006253 mouse movement, 15 patients): again no difference (+0.010 AUC, p = 0.73).