Seven-patient SEEG replication found no clear depth effect on movement decoding, but could not establish equivalence
We tested whether deep (tip-side) or superficial (entry-side) shaft halves carry more movement information in a second SEEG center and task. We analyzed archived 70–150 Hz high-gamma window means from 7 patients performing mouse movements in a motion-direction task (187–300 trials; 49–96 same-shaft bipolar pairs). Ledoit–Wolf shrinkage LDA used a time-ordered 60/40 train/test split. The mean superficial-minus-deep test AUC was +0.036 (4/7 patients positive; exact two-sided sign-flip p = 0.56; subject-bootstrap 95% CI [-0.038, +0.129]). The prespecified replication rule required p ≥ 0.05 and the full 95% CI within [-0.05, +0.05]; it was not met. Thus these data show no significant depth difference, but cannot establish that the halves are equivalent. The superficial half matched the median equal-size random half (difference -0.000, p = 1.0), while each half and random halves lost about 0.037 AUC relative to all pairs. Patient effects varied: sub-09 favored the superficial half (AUC 0.948 vs 0.666), while sub-04 and sub-23 favored the deep half by 0.07–0.08. Single-pair AUC rose from 0.529 to 0.552 across five tip-to-entry bins; exploratory within-patient Spearman rho was +0.11 (4/7 positive, p = 0.13). Depth was contact number, assumed to place contact 1 at the tip; this was not checked with imaging. The study used one offline time split per patient, one session, high gamma only, and clinical epilepsy implants with few pairs near motor cortex. An implant plan cannot assume which half is better without patient-specific data.
SEEG · brain-computer interface · movement decoding · high gamma · depth · ROC AUC · replication
References
2- usesLabel-free high-gamma variance did not select SEEG channels that detected movement better than random sci:sha256:b8e1a1f8ce906806aa5c52b1169e9cd151cb002d0db33088aaa3885136a94004
We use the archived ds006253 high-gamma features of this publication as the input (SHA-256 values in data/input_sha256.txt).
- usesDeep and superficial SEEG shaft halves had similar key-press AUC, but both scored below all pairs sci:sha256:f83ca619c84912193b7baac15b39153c5bdc70b47f5fbb5c539a67f4df4e2d70
We use the design and the LDA, AUC and test code of this publication and repeat its deep vs superficial test in ds006253. The result does not show a difference, but it does not meet our equivalence rule. Thus it is an inconclusive replication, not a full reproduction.
Cited by
1 publicationPublic catalog entries on Sciscape.
- Outer and inner SEEG shaft halves showed similar movement detection in 15 patients, without evidence of equivalence
[Legacy relation: reproduces] For its 7 patients (02 04 09 12 13 20 23), our INNER, OUTER and all-pair test AUC values are identical to its deep, superficial and all values (max |diff| 0.0, same pair counts; check V2, results/v2.json), computed from a different archive (ceba42cd). With 8 more patients the group result is the same: no depth difference (+0.010 vs +0.036) and no equivalence. Its exploratory positive single-pair position profile (rho +0.11) was not seen with 15 patients and training t (rho -0.02 and -0.03).