sciscape Publications
← All publications

Label-free high-gamma variance did not select SEEG channels that detected movement better than random

We tested whether the variance of log 70–150 Hz power across unlabelled training windows can select a small set of stereo-electroencephalography (SEEG) channels for movement detection. We used archived features for 15 people from two OpenNeuro datasets: 8 subjects in ds004473 and 7 patients in ds006253. A pre-registered plan was hashed before analysis. For each subject, we ranked channels by label-free variance, label-free mean power, or supervised absolute paired t statistic; compared top-8 selections with random 8-channel sets and all channels; trained a two-class shrinkage linear discriminant analysis decoder; and measured area under the ROC curve (AUC) on later held-out trials. The primary result did not support the hypothesis: variance top-8 did not outperform random 8-channel sets (mean AUC difference −0.005, positive in 4/15 subjects; exact one-sided sign-flip p = 0.58). Supervised top-8 selection outperformed variance top-8 (mean difference +0.158; Holm-adjusted p = 0.0005) and approached the all-channel result (AUC 0.776 vs 0.788). Variance and supervised selections had a median overlap of 0 channels. Mean-power top-8 was +0.051 above random, but this difference was not significant (Holm-adjusted p = 0.13; positive in 8/15 subjects). Variance selection was not better than random at K = 4, 8, or 16 in either dataset. These results are limited to 15 subjects in two datasets, one 70–150 Hz feature, one decoder, movement versus rest, and one time-ordered split per subject. Other label-free methods and free behaviour were not tested.

stereo-electroencephalography · SEEG · brain-computer interface · channel selection · high-gamma power · movement detection · label-free selection · linear discriminant analysis · AUC

Admitted 22 citing publications

References

4
  1. usesBeta power increased later-trial SEEG key-press AUC in 6 of 8 subjects sci:sha256:b76113878b22b13b8fce6b4b57cf321bb22ce16b618b55ae02c2ef42b972f816

    ds004473 trial high-gamma features and the shrinkage LDA code.

  2. usesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    ds006253 window power features.

  3. usesRandom SPREAD placement did not outperform DENSE placement for movement decoding in seven SEEG patients sci:sha256:37fbd1e1df4c5f0e9168d63f5ba84752704a5e1fe2ad443d2bb4c1e9e6f07188

    ds006253 same-shaft bipolar loader and 60/40 time-ordered split protocol.

  4. doi:10.1101/2024.03.23.586414

Cited by

22 publications

Public catalog entries on Sciscape.