Decrease channels carry held-out movement information and improve equal-size SEEG decoding in 15 subjects
We tested whether bipolar stereo-electroencephalography (SEEG) channels with lower log 70–150 Hz power during movement carry information about movement on later trials. We used archived features from 15 subjects in two datasets (ds004473, 8 subjects; ds006253, 7 subjects), ranked channels on training trials by paired move–rest t statistics, and evaluated shrinkage linear discriminant analysis on time-ordered held-out trials. The eight channels with the largest decreases (NEG8) had mean held-out AUC 0.667; all 15 subjects had AUC above 0.5 (Holm-adjusted p = 6.1 × 10⁻⁵). Combining eight increase and eight decrease channels (MIX16) gave mean AUC 0.783, 0.068 above the 16 largest-increase channels (POS16), in 14 of 15 subjects (Holm-adjusted p = 9.2 × 10⁻⁵). NEG8 channels retained a negative test-set t statistic in 92.5% of channels; their mean test move–rest difference was −0.064 log units in all 15 subjects. MIX16 was close to using all channels (AUC 0.783 vs 0.788). These results show that a map based only on high-gamma increases can discard reproducible movement information in these data. The study used two datasets, one feature, one decoder, movement-versus-rest classification, offline evaluation, and one time-ordered split per subject; it did not test why power decreased or analyze channel anatomy.
stereo-electroencephalography · SEEG · brain-computer interface · movement decoding · high gamma · power suppression · shrinkage LDA · held-out evaluation
References
5- usesBeta power increased later-trial SEEG key-press AUC in 6 of 8 subjects sci:sha256:b76113878b22b13b8fce6b4b57cf321bb22ce16b618b55ae02c2ef42b972f816
Source of the ds004473 bipolar 70-150 Hz trial features.
- usesLabel-free high-gamma variance did not select SEEG channels that detected movement better than random sci:sha256:b8e1a1f8ce906806aa5c52b1169e9cd151cb002d0db33088aaa3885136a94004
Archived 15-subject features, loaders, splits and LDA code reused unchanged.
- usesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f
Source of the ds006253 window power features.
- usesRandom SPREAD placement did not outperform DENSE placement for movement decoding in seven SEEG patients sci:sha256:37fbd1e1df4c5f0e9168d63f5ba84752704a5e1fe2ad443d2bb4c1e9e6f07188
Source of the ds006253 loader and 60/40 time-ordered split.
- doi:10.1101/2024.03.23.586414
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.