Stimulus-locked labels detect movement above chance but underperform onset-locked labels in seven SEEG patients
In an offline analysis of seven SEEG patients performing random-dot motion decisions with mouse movement, stimulus-locked calibration labels detected movement above chance but did not meet a 0.05-AUC non-inferiority margin against onset-locked labels. With Ledoit-Wolf shrinkage LDA on 70–150 Hz features, mean AUC was 0.694 for stimulus-locked labels and 0.788 for onset-locked labels (mean difference −0.094; three of seven patients within the margin; p = 0.76, Holm-adjusted p = 0.76). Stimulus-locked labels from training trials with reaction time at least 0.5 s, so the label window contained no movement onset, still detected movement in all seven patients (mean AUC 0.685; p = 0.0078, Holm-adjusted p = 0.016). This detector was 0.095 AUC lower than an onset-locked detector trained on the same trials (all seven patients lower; two-sided p = 0.031). Across 0.2 s bins, the decoders were similar from 0.4 s before movement onset to onset and lower for stimulus-locked labels from onset through 1 s after. These findings suggest that stimulus-locked labels mainly train on decision and preparation activity rather than movement execution. The result is limited to offline overt mouse movement, seven patients, one session and time-ordered split per patient, one feature and one decoder; it does not establish performance for attempted movement by paralyzed users.
brain-computer interface · SEEG · movement detection · calibration labels · stimulus-locked · movement onset · shrinkage LDA · high-gamma activity · AUC · non-inferiority
References
5- usesLabel-free high-gamma variance did not select SEEG channels that detected movement better than random sci:sha256:b8e1a1f8ce906806aa5c52b1169e9cd151cb002d0db33088aaa3885136a94004
Archived ds006253 per-trial window features (data/ds006253) and the numpy shrinkage LDA code/lda_np.py, copied unchanged; same channel filter and 60/40 time-ordered split.
- supportsIn seven SEEG patients, movement-detector timing was stimulus-locked (mean latency slope 0.02); post-stimulus hard negatives did not change it sci:sha256:43b8e57b45f4eb585d0522b1bda62811d03a481ec4938c65c935192852f21873
That work found detector onset follows the stimulus. Our stimulus-locked labels capture the pre-onset part of the movement response as well as onset-locked labels do, consistent with this.
- usesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f
Original extraction of the ds006253 HGA window and 0.2 s bin features (code/extract.py there), with source S3 keys and SHA-256 in the prov.json files.
- supportsIn five patients, a 70–150 Hz SEEG movement detector also scored visual stimulus periods highly sci:sha256:15f05b5465a987bcbeecc6cc162a2bce898262ac7004b2e313258f644479e9f8
That work showed an onset-locked detector also responds after the stimulus. Here the reverse holds: a stimulus-locked detector responds to movement, and both decoders are equal in the 0.4 s before onset, which agrees with shared stimulus/decision activity.
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The analysis uses archived per-trial 70–150 Hz features derived from OpenNeuro ds006253. Provenance records identify source HGA and behavior files by S3 key and SHA-256; the exact dataset release is recorded as 1.0.3.