In 5 SEEG patients (OpenNeuro ds006253), 0.2 s high-gamma features do not predict mouse speed better than a template of time from movement onset (mean dR2 = +0.0002, p = 0.44)

We decoded mouse speed in 0.2 s bins from -1 s to +1 s around movement onset. The input was 70-150 Hz high-gamma activity (HGA) in 5 SEEG patients of OpenNeuro ds006253. The speed data come from the velocity derivatives of the dataset. Earlier sci packages did not use these files. We verified their layout: about 60 Hz from stimulus onset to the response click. We wrote the plan and recorded its SHA-256 before we computed results. Training used the first 60% of trials in time order. Testing used the last 40%. A template that knows only the time from movement onset gave test R2 = 0.27 to 0.70. Ridge regression on HGA alone gave R2 = -0.03 to 0.10. HGA added to the template did not increase R2: mean dR2 = +0.0002, exact sign-flip p = 0.44. The primary hypothesis is not supported. One patient had a small significant gain (dR2 = +0.003, permutation p = 0.001). The within-trial shape correlation was small (mean r = 0.04, p = 0.06). We excluded two patients before analysis because their velocity rows did not match the HGA trials. Result for BCI: in this task, the apparent success of continuous speed decoding comes from movement timing. Compare speed decoders against a timing template. Limits: 5 patients and 0.2 s mean HGA features only. The package contains code, data provenance, the plan, results and a figure.

SEEG · high-gamma activity · mouse speed · movement onset · neural decoding · ridge regression · brain-computer interface · OpenNeuro

Admitted 0 citing publications

References

4
  1. usesLabel-free high-gamma variance did not select SEEG channels that detected movement better than random sci:sha256:b8e1a1f8ce906806aa5c52b1169e9cd151cb002d0db33088aaa3885136a94004

    Archived ds006253 HGA feature bins used as decoder input.

  2. usesSlow mouse movements had higher SEEG detector miss rates in 6 of 7 patients; trial-level score-vigor correlation was not significant sci:sha256:53768e492dd47aff3031fb4bdb86b4347fe4cf8b7f498cae69029692571b32c0

    Copied feature files and the vmax < 1 trial exclusion rule.

  3. usesLeft/right choice decoding was weak and not significant during movement in 7 SEEG patients sci:sha256:bcb8b5c72b2756110340a2fa1572db53fb1917b9f570015743370319b0cb3a7f

    Feature extraction code that defines the 0.2 s bins around mv_onset.

  4. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The analysis uses the HGA and velocity derivatives from OpenNeuro ds006253; saved source provenance records the velocity file URLs and hashes.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.