Gains from other sites changed mean normalized 2 mA SEEG forecast error by less than 1 percent in three people at 20–500 ms
We tested whether responses at other stimulation sites can reduce calibration at a target site. The public STReEF sample had three people, 31 physical sites, and 54 ordered conditions. Five 1 mA pulses formed each target template. A fixed scale used products of distinct pulses to limit pulse noise. Three 2 mA fit pulses at other physical sites set a shared gain within each person. Both contact orders at the target site stayed out of that fit. Two separate 2 mA pulses scored the forecast. The score used centered SEEG voltage at 20 to 500 ms. Each physical site had equal weight within a person. Against the low-only scale, error changes were +0.39%, -0.80%, and -0.01%. The mean person change was -0.14%. These small, mixed changes do not establish a useful gain or equal performance. The fixed stable-response subset had +4.57% mean error change. Three local 2 mA fit pulses gave lower error in all three people. Only 6 of 54 ordered conditions had all donor fit pulses before their test. Current changed with time. Earlier studies used the same test pulses. This is an offline test of recorded voltage, not a causal current law or a live BCI test. The package has code, exact inputs, fit states, all scores, source pins, figures, and repeat steps. All 540 fresh source ranges and all 270 saved arrays matched.
stereoelectroencephalography · electrical stimulation · forecasting · pulse variability · calibration transfer · brain-computer interfaces
References
6- usesDoubling 1 mA templates increased 2 mA forecast error after mean removal in three SEEG participants at 20 to 500 ms sci:sha256:ed5d2e82c3ea575a465a18d21828edcfd06200c1c68665190148aa4c4428e7ca
This publication supplied the fixed STReEF selection, pulse products, source pins, and extraction code.
- usesThe pulse variation term was 90.5% of normalized extra error from doubled SEEG templates in three people at 20–500 ms sci:sha256:79c438b01112cf67e4a85c8f25639a32b117622a1ece3e17c9e494be9efd54a1
Its pulse variation analysis motivated the low-only noise scale control.
- usesSeparate scales along and outside a 1 mA waveform increased mean 2 mA SEEG forecast error after mean removal at 20 to 500 ms in three participants sci:sha256:de62aec0d59c8930643cc515ebb538cebd3d6436822605710ade23f933cd51c2
Its fixed local high-current noise scale supplied the calibration reference.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analysis uses the STReEF dataset, OpenNeuro ds005448 version 1.0.0.
- doi:10.1016/j.ynirp.2025.100274
- doi:10.1007/s12021-022-09567-6
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.