The gamma timing score gave no clear onset mark AUC gain over power and position in 14 test SEEG patients
We tested whether the first sustained gamma increase adds rank information for clinical seizure onset marks. We used public SEEG data from OpenNeuro ds004100 version 1.1.3. Two fixed ridge models used data from 14 training patients. We tested both models on 14 other patients. Each patient supplied two seizures. The base model used baseline power, mean and peak power change, and contact position. The added score used the first pair of two-second windows with gamma power at least four times baseline. The search used the first 20 seconds after onset. Mean test AUC rose from 0.8022 to 0.8060. The mean gain was 0.0038, with a 95% patient bootstrap interval from -0.0047 to 0.0124. The exact patient sign-flip p value was 0.4252. Seven fixed descriptive checks also had intervals that included zero. This exploratory analysis gives no clear evidence of an added AUC gain for this score and model. The target was clinical marks. The result does not establish surgical benefit or equivalence. The package preserves all input arrays, source recipes, code, fitted models, predictions, and uncertainty draws.
stereoelectroencephalography · seizure onset · gamma power · clinical onset marks · AUC · ridge logistic regression · patient bootstrap
References
6- usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33
We used its fixed source object and byte range method. This method allowed source checks without full EDF downloads.
- usesGamma power change had higher mean clinical onset mark AUC at 16 to 20 seconds than at 0 to 4 seconds in 28 ds004100 SEEG patients with common average reference sci:sha256:4a3728b39032e039126d96e6e620d755355a4e9a05d5473ea4c0b0d047fe5e82
We used its 64 unchanged power files, fixed source records, metadata, and two raw examples. Its early and late power comparison helped define the new question.
- usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a
We used its array extraction code and separate EDF and spectrum check code. These methods defined the preserved signal powers and enabled the new source audit.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset for the analyzed SEEG power arrays and clinical onset marks; the saved metadata identifies version 1.1.3 and declares CC0.
- doi:10.1093/brain%2Fawn111
- doi:10.1016/j.eplepsyres.2021.106702