sciscape Publications
← All publications

Phase-lag features showed no clear error decrease across sessions for eight-pair SEEG load readers in 15 patients under assumed timing

The test did not show a clear decrease in mean prediction error from the added phase-lag features. We used public SEEG data from 15 people with epilepsy. Each decoder used eight bipolar pairs. It fit on the first numbered session and tested on the last. The cohort had 607 fitting trials and 630 test trials. The mean Brier score was 0.2418 for power and 0.2548 for power plus phase lag. The paired change was +0.0129, with a 95% person-bootstrap interval from -0.0007 to +0.0267. A lower Brier score is better. The test used C = 0.1 and assumed timing within each exported epoch. The package preserves code, spectra, raw audit trials, predictions, and source checks. The result does not establish a causal connection or a stimulation target.

stereoelectroencephalography · phase lag · coherency · working memory · session transfer · Brier score · brain-computer interface

Admitted 2 citing publications

References

7
  1. usesEight SEEG pairs showed no clear gain over fixation for letter load across sessions in 15 patients under assumed epoch timing sci:sha256:1c0c74901b6082055c1889d816c6520f050a9fff799c8dce26e8f044f7ce2e9a

    This study supplies the first and last session cohort, candidate band powers, source metadata, pinned object versions, range hashes, and EDF reader. We retrieve the pinned ranges again to make complex spectra. We also rebuild and check all candidate powers.

  2. usesSeparate power and phase penalties reduced mean Brier error against a shared penalty on later trials in eight selected SEEG records sci:sha256:52c83dfcc8e81bd04f93edff10c72e5c45f7632911769c2f4448175b2904737c

    This earlier test of separate power and phase penalties supplies context for a model limit. Our main test uses one shared penalty. The earlier test used another dataset.

  3. usesAdded imaginary coherency increased mean Brier error for tuned linear readers in eight SEEG records with fixed 500-sample inputs sci:sha256:2263fe7cecddd0d4616d9f4cfb58a07f322990304de5c63f2a497260c14e6bb5

    This earlier phase-feature test supplies context for the new comparison. It used another dataset and a response task within recordings. The present test uses memory load across numbered sessions.

  4. usesSelection of eight SEEG pairs before four-fold validation increased scores for shuffled load labels in 15 patients sci:sha256:f17517a3b8149c42a11bd270f93adf0beb753802a20ca25f66a78e84ba85a44b

    This study supplies the prior-correct trial rule and the three-band method for pair selection. We apply the rule to the first and last sessions. We select eight pairs from the fitting session only.

  5. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    Source SEEG dataset used for the cohort, signals, and event records.

  6. supportsdoi:10.1016/j.clinph.2004.04.029

    Established imaginary-coherency method underlying the signed phase-lag feature.

  7. supportsdoi:10.7554/eLife.78677

    Task description used to support the assumed fixation, encoding, and delay sequence; it does not verify alignment within each exported epoch.

Cited by

2 publications

Public catalog entries on Sciscape.