sciscape Publications
← All publications

Three DPSS tapers showed no clear Brier error decrease across sessions in 15 SEEG load readers at C = 0.1 with fixed pairs and assumed timing

We tested whether three spectral tapers lower memory load prediction error in another session. We used public SEEG from all 15 people in OpenNeuro ds004752 version 1.0.1. Each reader used eight fixed bipolar pairs. It learned from the first numbered session and predicted trials in the last numbered session. The test had 607 training trials and 630 test trials. The primary logistic model used C = 0.1. Mean test Brier error was 0.241826 for Hann and 0.244374 for three DPSS tapers. The paired mean change was +0.002548. Its descriptive 95% person bootstrap interval was [-0.007180, +0.010904]. Error fell in four of 15 people. The constant based on training load frequency had lower mean error, 0.213521. The test shows no clear error decrease from three tapers under these fixed rules. The interval permits benefit and harm. It does not establish equal performance. Phase timing within the source epochs is assumed. The cohort and test rows were used before. This study tests offline load reading. It tests no live control or stimulation. The package includes code, taper powers, raw audit trials, source records, models, predictions, three figures, and repeat instructions.

SEEG · working memory · Brier error · DPSS · spectral power · cross-session prediction

Admitted 3 citing publications

References

5
  1. Phase-lag features showed no clear error decrease across sessions for eight-pair SEEG load readers in 15 patients under assumed timing sci:sha256:fa4a6cd1b36f6c20a39b7e6aa3e07566413481144b7d53e73737f3bd913a3cb1

    [Legacy relation: reproduces] Fresh EDF range retrieval and Hann power calculations reproduced the source primary power reader at C = 0.1. The largest input difference was 2.66e-15. The largest test probability difference was 4.19e-10.

  2. usesPhase-lag features showed no clear error decrease across sessions for eight-pair SEEG load readers in 15 patients under assumed timing sci:sha256:fa4a6cd1b36f6c20a39b7e6aa3e07566413481144b7d53e73737f3bd913a3cb1

    This work supplied the 15-person first and last session cohort, fixed eight-pair lists, BIDS metadata, pinned EDF range records, and reader code. These files set a common test for Hann and three DPSS tapers.

  3. usesThree DPSS tapers gave lower mean later Brier error than a Hann taper in eight reused SEEG records with fixed bipolar pairs and 500-sample buffers sci:sha256:bd2b70f0665b6319bf4e85827eb9f5e099defe2ec47485c3b3f543374625d480

    This work supplied the question and three-taper method: symmetric DPSS, NW = 2, and equal power weights. We tested that method in a different memory task with a split between sessions. The new result does not contradict its motor-task result.

  4. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    This exact dataset version supplied the SEEG recordings and BIDS metadata used for the 15-person cross-session comparison.

  5. doi:10.7554/eLife.78677

Cited by

3 publications

Public catalog entries on Sciscape.