30 to 80 Hz bipolar slope maps retained mean correlation 0.841 after linear shaft trend removal in paired 60 s files from 33 SEEG patients
We tested bipolar slope maps in two public SEEG files per patient from OpenNeuro ds004100 version 1.1.3. The test used the first 60 seconds of each file and 33 eligible patients. The fit used 30 to 80 Hz, with 55 to 65 Hz removed. We selected 1,799 pairs without shared contacts. After removal of shaft means and linear contact-order terms, the mean patient correlation was 0.841. The patient bootstrap 95 percent interval was 0.804 to 0.877 under independent and exchangeable patient resampling. All 33 patients had positive correlations. All eight fixed descriptive checks also had positive scores in every patient. All 504 arrays rebuilt from 72 pinned raw excerpts matched exactly. The package preserves code, spectra, source versions and hashes, results, bootstrap draws, figures, and reproduction instructions. The files have unknown recording separation. Nonlinear anatomical and recording effects can remain. This result measures file agreement and does not establish a stable neural trait.
stereoelectroencephalography · SEEG · spectral slope · bipolar reference · intracranial EEG · spatial residualization · file agreement
References
6- usesCommon average reference raises median relative gamma rank agreement in two 60 s SEEG records from each of 36 HUP patients sci:sha256:3f5f9f6ae779730a7bf70359ae9ddc56a5032c2e8abdb97c0cf3c127d6082e74
The fixed good-contact list and EDF reader came from this study. We preserved its reader and license through the direct source archive.
- usesMean bipolar reference effects exceeded file differences for 30–80 Hz slopes in paired 60 s SEEG records from 36 patients sci:sha256:a343645ba027d704e981c68fea0352745ba1410c491d9bbbcc42ef099ff50447
We used the paired spectra, fixed contact list, extraction methods, and raw retrieval pins. We rebuilt all 504 spectrum arrays. We tested agreement after shaft trend removal.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Provides the public SEEG recordings used in this analysis; the saved evidence identifies the exact version as CC0.
- supportsdoi:10.1523/ENEURO.0492-21.2022
Supports the background statement that electrode location and reference choice affect the spatial spread of intracranial signals.
- supportsdoi:10.1088/1741-2552%2Fae1b3b
Supports the background statement that bipolar pair distance can affect signal power in a frequency-dependent way.
- supportsdoi:10.1038/s41593-020-00744-x
Supports the methods limitation that a band slope does not separate spectral peaks from the aperiodic component.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedes30 to 80 Hz bipolar slope maps retained mean correlation 0.841 after linear shaft trend removal in paired 60 s files from 33 SEEG patients
This version includes the inherited source checksum file in the root hash list. It adds a complete hash coverage check. The scientific results are unchanged.