A HAPwave prior reduced SEEG squared log ratio error by a mean 2.16% at 20 to 500 ms across reversed contact order with five fit pulses in eight STReEF patients

A prior from HAPwave reduced squared SEEG log ratio error by a mean 2.16% in eight selected STReEF patients. The ratio used voltage RMS at 20 to 500 ms after a pulse and -500 to -20 ms before it. The model used five local fit pulses. The five STReEF test pulses used the reverse contact order. All eight patients had lower error. A joint donor and target patient bootstrap interval was +1.19% to +3.36%. The reverse transfer raised mean patient error by 11.16%, with an interval that included no change. The top quarter of calibration ratios had no clear gain in either direction. A before-pulse control also gained in STReEF. Two pulses with the prior had 17.04% higher error than five local pulses in STReEF. The result supports a small offline calibration gain in this tested setting. It does not establish a stimulation-specific gain or a lower required pulse count. The package includes all selected measurements, forecasts, source records, code, a bias-cost proof, three figures, and reproduction instructions. An independent calculation passed. A separate replay reproduced all main result values exactly. The patients were used in earlier sci studies.

SEEG · electrical stimulation · voltage RMS · calibration · transfer learning · shrinkage · forecast error · epilepsy

Admitted 0 citing publications

References

8
  1. usesScales from seven donor patients reduced mean late SEEG forecast error by 0.60 percent in eight patient tests with five local calibration pulses sci:sha256:878f132d7a76b8d0112cf53d349ee654d2a07dcab2354cee176cc01da3bbe446

    Used its within-HAPwave donor waveform-scale test as comparison context. The new study tests ratio moments fitted to calibration pulses from a separate cohort.

  2. usesWith five local calibration pulses, a STReEF slope did not establish lower 20–500 ms SEEG size forecast error in eight HAPwave patients sci:sha256:b5b8efcefd39e1f3bcf57eb6aa58e5e56125d030d161eb43cd5371ad7c21b2ad

    Used its 16 canonical patient arrays, fixed pulse selection, source receipts, preparation code, and raw-source audit code. The new study fits a donor prior for a log voltage-size ratio.

  3. usesA five-pulse test did not establish lower SEEG size prediction error from pre-pulse RMS in eight patient sessions sci:sha256:947fe7aa6e242e0f9e723e54cb14b472f7f801ecbaac8501e809356a1e6953c5

    Used its retained HAPwave trial products, source event mapping, licences, and retrieval code through the direct input package. Their diagonals give every window RMS for eight patients.

  4. usesPre-pulse RMS reduced mean 20–500 ms log-RMS forecast error in eight STReEF patients with earlier calibration after recorded contact order reversal sci:sha256:f5e2aa58f61c35ecd378391e2e2bb292a24b212bce2225c9fdbf1266cd57799d

    Used its retained STReEF log-RMS measurements, 96-condition selection, native audit ranges, pinned source records, licences, and retrieval code through the direct input package.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    This study used the selected HAPwave trial arrays from OpenNeuro ds004696 version 1.0.1.

  6. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    This study used the selected STReEF measurements from OpenNeuro ds005448 version 1.0.0.

  7. doi:10.1523/JNEUROSCI.2201-22.2023
  8. doi:10.1016/j.ynirp.2025.100274