Shaft-end bipolar pairs had higher 70–150 Hz power in 15 SEEG patients, with similar excess at both ends
This preregistered replication tested a post hoc finding in independent OpenNeuro ds004752 data from 15 patients performing a verbal working-memory task. Using the first 64 s of session 1 for each patient, we found that the highest-power 70–150 Hz bipolar pair was at a shaft end in 10/15 patients (4.30 expected; Holm-adjusted p = 0.0076). End pairs had higher power than interior pairs in all 15 patients (mean AUC = 0.754; Holm-adjusted p = 1.5 × 10⁻⁴). The outer and tip ends had similar power (mean difference +0.006 log₁₀; 6/15 positive; p = 0.48). Outer-end pairs had a flatter spectrum (mean difference +0.238; Holm-adjusted p = 0.0049), while their envelope correlation difference was not significant after Holm correction (p = 0.11). Thus, the shaft-end power excess recurred, but was not specific to the superficial end; the planned criteria for an EMG explanation were not met. This was a single-site, single-task study of 15 patients using 64 s per patient, without gray/white matter labels. The outer end was defined by distance from the contact centroid, not the skull. A possible tissue-related cause was not tested.
stereo-EEG · SEEG · high-frequency activity · bipolar pairs · electrode shaft · working memory · replication · power spectrum
References
4- usesIn 71 completed OpenNeuro iEEG datasets, 42 contained SEEG channels across 1,167 subjects sci:sha256:79a420e35329acba12ac65e4e29aee4286ecfce55fed09cf0b4967a9658202a9
Its SEEG dataset census was used to select ds004752, a cohort that 5d94e249 did not use.
- supportsTop interictal HFA misses in SEEG were not spatially near the clinical seizure onset zone sci:sha256:23542aa782c15a366aad81aa1446fbd1fec8544ecc3ae48ddf2e6d84b8d25c3d
Pre-registered test of its post hoc E2 (top HFA pair at a shaft end) in an independent cohort (ds004752): H1a and H1b are significant. The excess is at both shaft ends, not only at the superficial end.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The study analyzed session 1, run 1 recordings from 15 patients in OpenNeuro ds004752; saved metadata identifies release 1.0.1 and its CC0 license.
- doi:10.7554/eLife.78677
Cited by
2 publicationsPublic catalog entries on Sciscape.
- challengesShaft-end HFA excess in 45 SEEG patients is partly tissue-linked and remains at the deep tip
This study finds the unadjusted shaft-end HFA excess in a second cohort, but tissue class explains about half of it, and the remaining excess is at the deep tip only. The outer end has less HFA than the interior. This does not agree with the equal tip and outer excess and the tissue-independent interpretation in 77c2e9ca.
- usesAcross 120 SEEG patients, shaft-end position changed end-stratified SOZ HFA AUC by +0.002
Its shaft-end HFA excess in task SEEG is the confound that we tested in interictal SOZ data.