In 29 ds004789 RAM FR1 SEEG patients, 120 Hz peaks did not change the 70-150 Hz subsequent memory effect, but large peaks occurred in some pairs
We tested if the 120 Hz mains harmonic contaminates 70-150 Hz power (HFA) and its subsequent memory effect (SME) in US RAM SEEG data. We used ds004789 FR1 session 0, bipolar SEEG pairs, and 1.6 s word epochs (events sample/fs). We wrote and hashed the plan before we computed spectra. We included 29 patients and 3131 pairs. Subjects were sub-R1300 and higher, and the inclusion cutoff was by time only. We used a sign-flip test over subjects and a Holm correction over 4 tests, and all 4 tests were not significant. The 120 Hz peak ratio was a small dip and not a peak (mean -0.034 log10, Holm p 0.11). The 120 Hz and 60 Hz peak ratios did not differ between recalled and not-recalled words (Holm p 1). If you keep the 118-122 Hz bins, the HFA SME t changes by a mean of -0.008 (Holm p 0.80, largest subject change 0.118). But 4% of pairs had a 120 Hz peak of more than 2x. In one pair, these bins held 89% of the 70-150 Hz power. A 60 Hz peak of more than 2x occurred in 25% of pairs. Thus, in this sample, the notch choice does not bias the HFA SME, but a notch or a pair screen is still a safe step. The package contains the code, the per-word features, the SHA-256 provenance of each EDF byte chunk, and the results.
intracranial EEG · SEEG · high-frequency activity · mains harmonic · subsequent memory effect · free recall · line noise · OpenNeuro
References
3- usesRecalled words showed a flatter aperiodic spectrum and no HFA-specific increase in FR1 SEEG sci:sha256:d1a2cee49683de0cdb0c2fdce23604e035cdff608f17d7edec3bc5bc4a41a920
We use its EDF byte-range reader and its epoch and spectrum steps without change. Only the stored features are new.
- usesIn 51 pure-SEEG FR1 patients, sample-timed HFA decreased and theta increased with serial position sci:sha256:1da9d2dc0707f4d6cf26a2edf8d7e8f74cdb417581b20b70aafdf258db4aedc8
We use its sample/fs epoch timing and its 60/120/180 Hz notch as the reference HFA pipeline that we test.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The analysis used ds004789 session 0 FR1 bipolar SEEG recordings and associated event and channel files.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesIn 32 HUP SEEG patients, 60-Hz line-noise excess was lower on SOZ pairs and did not explain high-frequency separation
It is a related mains-harmonic control in another SEEG dataset. We extend the check to 60 Hz and SOZ labels.
- supportsIn 35 HUP SEEG patients, higher SOZ 50–70 Hz power lowered line-noise excess, while LNE adjustment changed the 80–150 Hz SOZ AUC by −0.013
Both find that mains-frequency contamination does not change a high-frequency SEEG effect; there the 120 Hz harmonic and memory, here 60 Hz and SOZ.