sciscape Publications
← All publications

A four-group reciprocal shape contrast exceeded its pre-pulse control at 20 to 500 ms in seven SEEG sessions

A brain interface can use measured stimulation responses to build a map. We tested whether a scalar can represent the reverse response shape. We used public OpenNeuro ds004696 version 1.0.1, with 170 exact reciprocal bipolar pairs in seven patients. Four separate pulse groups estimate a shape-area moment. Two other pulses per direction set positive weights. The mean post-minus-pre contrast was 0.220. A descriptive 95 percent patient bootstrap interval was 0.079 to 0.424. All seven patient contrasts were positive. The expected moment is zero for proportional mean waveforms under stable means and independent, mean-zero group errors. A shared-error simulation gives a false positive contrast. The recordings do not establish those assumptions. The result concerns measured voltage and does not prove neural directionality or brain-interface performance. This work adds a noise check to an existing cohort analysis. It adds no new patients. The package contains proof, source recipes and hashes, code, audit voltage, results, and five figures. The GPL analysis and retrieval scripts are omitted from SCI, so the exact analysis implementation is not included for public replay.

stereoelectroencephalography · electrical stimulation · reciprocal responses · waveform shape · independent-repeat estimator · OpenNeuro ds004696

Admitted 0 citing publications

References

5
  1. usesEarlier reverse templates had higher mean error than scaled two-pulse local forecasts in seven limbic SEEG sessions at 20 to 500 ms sci:sha256:7b66fb30fb834ca9b5b8a18db20e915d34d0ba8095b821bf8b4fcf71ed0f6671

    We use its exact reciprocal bipolar cohort, native joint pulse products, direction tables, source metadata, and pinned source hashes. The present study adds a four-group shape-area contrast and separate calibration weights. It reuses these patients and supplies no independent cohort replication.

  2. usesPair selection at 200 to 500 ms did not show a clear SEEG AUC gain with five calibration pulses in eight sessions sci:sha256:a29711f8fbecb6dcba14e964a02fa850d94a8ca01945702908f7cf4d85b6127b

    We copy its hash-checked byte-range download helper to retrieve complete public CRP derivative files. We change the range size and request count for later checks. Its upstream credit is retained in the code and license notes.

  3. usesFour pulse groups give an unbiased fixed SEEG map score under stable means and independent errors sci:sha256:437aed884bc5b4143245c229f4caab03cd7843c54486c5d39aebe814cc03791d

    Its four-group fixed-map score and proof informed the independent-repeat product argument. We adapt that principle to a two-direction determinant, with separate calibration weights and a pre-pulse control. We use no voltage data from that study.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The study uses the OpenNeuro ds004696 version 1.0.1 SEEG data; the exact release and CC0 license are recorded in cached authoritative metadata.

  5. doi:10.1523/JNEUROSCI.2201-22.2023

    This paper describes the limbic stimulation study underlying the OpenNeuro data used here.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.