Covariance angles kept 37.9 percent mean site accuracy under nine simulated positive common voltage gains in five offline SEEG sessions

We tested stimulation site identification under simulated common voltage gains in public SEEG data from five patient sessions. The test had 183 sites and 732 separate test pulses after four calibration pulses per site. A signed angle rule used the calibration covariance. It kept all decisions and 37.9 percent equal-patient mean accuracy at nine gains from -12 to 12 dB. A distance rule with the same templates and covariance had 40.6 percent accuracy at unchanged gain and 24.1 percent across -6 and +6 dB. The primary mean angle advantage was 13.82 percentage points. All five patient differences were positive. The exact two-sided sign-flip probability was 0.0625. The angle rule lost 2.62 points at unchanged gain. We also proved and checked a function for exact distance decision gain intervals. Only 16.8 percent of distance decisions stayed fixed across the full -6 to +6 dB range. Changing one output pair changed 22.2 percent of angle decisions on average. The proof requires a common positive gain and a fixed model. All public source hashes and raw reconstructions matched. The package gives code, inputs, scores, figures, provenance, and reproduction steps. This is a reused, same-session offline benchmark. It does not measure natural gain faults, a population effect, or live interface performance.

stereoelectroencephalography · brain stimulation · signal decoding · common voltage gain · covariance angle · template matching · decision stability

Admitted 7 citing publications

References

4
  1. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    We reused the archived contact bins, event data, source manifest, readout pairs, and site eligibility rules. We retained its calibration and test allocation and covariance distance rule. Its nominal predictions matched. The new angle and gain results use the same cohort.

  2. usesPower contrasts preserve fixed decisions under simulated broadband gain changes in eight SEEG recordings sci:sha256:68da70f80a5598956f61bc64b69eb4a62fc811e861e263de58c286a9e941c775

    This earlier fixed gain study provided a reference for related methods and their accuracy cost. It used power contrasts for a different task and dataset. No source signals or model arrays entered this analysis.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The five SEEG patient sessions and source files used in this analysis came from OpenNeuro ds004457 version 1.0.2.

  4. usesdoi:10.1523/JNEUROSCI.1325-22.2023

    This study produced the OpenNeuro recordings used in the benchmark.