SEEG variation ranks had greater agreement than mean waveform size ranks across contact order reversal at 20 to 500 ms in eight people
Five early pulses gave greater later SEEG rank agreement for variation than for mean waveform size in eight people with focal epilepsy. The fixed public sample had 96 stimulation conditions. Each condition had five early pulses and five later pulses after recorded contact order reversal. At 20 to 500 ms, the equal-person mean rank agreement was 0.908 for variation and 0.857 for mean waveform size. The difference was 0.052. It was positive in all eight people. The lowest variation quarter had a mean later variation percentile of 15.2 and a mean size percentile of 19.0. Before-pulse variation ranks also had high agreement. Stable background differences can contribute to the result. Time and contact order changed together. The study does not establish a causal order effect or better live interface performance. The package preserves exact products, native examples, code, figures, source versions, and checks of all 960 raw pulse ranges.
SEEG · intracranial EEG · rank agreement · waveform variation · stimulation · recording pairs · epilepsy
References
5- usesSEEG dispersion from five pulses showed no clear mean excess change after contact order reversal at 20 to 500 ms in eight people sci:sha256:28158b355bfb75703529ac30f2f8007322c773d858397cfb2baecf625f1326c8
This study uses the definition of five-pulse dispersion and the result on average dispersion change to choose a separate question about recording pair ranks. It reuses the cohort.
- usesA five-pulse check selected SEEG pairs with 60.8% mean shape agreement after contact order reversal at 20 to 500 ms in eight sessions sci:sha256:35cdaeabceeac5a3be97a54a264240386954c3bac2e4558f03b24d86d28e2bee
This study uses the fixed 96-condition sample, exact pulse products, source versions, and retrieval code. It adds rank agreement and later recording pair selection tests.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analyzed recordings are from STReEF, OpenNeuro ds005448 version 1.0.0; the package preserves source URLs, pinned object records, hashes, and the dataset credit.
- doi:10.1016/j.ynirp.2025.100274
- doi:10.1007/s12021-022-09567-6
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesWith signed gain fits, mean SEEG shape error rose across contact-order blocks beyond a before-pulse change at 20–500 ms in eight people
Exact STReEF waveform products, fixed sample, raw audit bytes, source metadata, and pinned retrieval code are the inputs.