A five-pulse shape check selected later repeatable SEEG readouts with 73 percent mean precision in eight patient sessions
This study tested a five-pulse shape check on public SEEG data from eight epilepsy patient sessions. It used 886 eligible readouts from OpenNeuro ds004696, version 1.0.1. The later test used two pulse groups that were separate from calibration. A size rule selected the same readout count at each stimulation site. Both rules selected 196 readouts. Mean patient precision was 73.2 percent for shape and 63.5 percent for size. The paired difference was 9.7 percentage points. The descriptive bootstrap 95 percent interval was 1.8 to 18.2 points. The primary exact sign-flip test gave p = 0.125. Four patients favored shape and four tied. Thus the primary test does not establish that shape selection is better. The package supplies a separate pulse benchmark, three figures, exact trial products, all selections, source hashes, and code. One public source derivative was rebuilt and matched the archive exactly. All stored data passed hash and numerical checks. The result concerns waveform agreement within a session. It does not establish better decoding or closed-loop control.
SEEG · electrical stimulation · waveform agreement · brain-computer interfaces · trial selection · signal processing
References
4- usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f
This study uses all 886 trial-product readouts, the chronological pulse index, the source metadata, and the adapted retrieval code. It tests separate later pulse groups and compares shape with size at equal readout counts within sites. The original first-five-versus-final-five precision is also reproduced.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis uses public SEEG data from this exact OpenNeuro snapshot; the source commit, retrieval URLs, file sizes, and hashes are preserved.
- doi:10.1523/JNEUROSCI.2201-22.2023
- doi:10.1371/journal.pcbi.1011105
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesPair selection within each fold reduced observed mean normalized error underestimation at 20–500 ms in eight SEEG sessions
Its early shape selection result supplied context for the recording selection question. Our local plan then tested error estimation after a different maximum M/D pair selection rule. We did not reuse its correlation cutoff.