A test did not detect a rise in excess squared residual correlation between shafts at 100 to 500 ms after stimulation in seven selected SEEG patients under patient independence and null sign symmetry
We tested whether excess squared residual waveform correlation between different SEEG shafts rises after single-pulse stimulation. The public source was OpenNeuro ds004696 version 1.0.1. The fixed selection had seven patients and 80 stimulation groups, with ten good exported pulses per group. Adjacent same-block contact differences gave 4,218 edges between distinct named shafts. We removed each pulse time mean and the mean waveform in two blocks of five pulses. The score was matching-pulse squared residual correlation minus its exact mean under within-block relative pulse permutations. This benchmark retains each pulse waveform and its temporal correlation. Patients had equal weight. The post window was 100 to 500 ms. The mean post-minus-pre change was +0.00111. The descriptive 95 percent patient interval was -0.00345 to +0.00553. The exact two-sided sign-flip p value was 0.6875 under patient independence and null sign symmetry. Five patients had positive changes. Planned descriptive checks had mixed directions and intervals that included zero. The test did not detect a rise. It does not establish a zero effect or physiological independence. The metric can miss shared inputs with different shapes or time delays. All seven freshly retrieved source files rebuilt the saved voltage arrays exactly. Independent calculations and a new process reproduced the result. The package preserves selected voltages, code, a proof of the benchmark, source versions and hashes, results, figures, and repeat instructions.
SEEG · electrical stimulation · residual correlation · waveform analysis · permutation benchmark · epilepsy
References
5- usesSEEG contact differences had higher waveform agreement after pulses in seven fixed limbic groups with block and time centering sci:sha256:a2e7c2ba04a9a4cf49425742ce8c6a88cbbae22e1b8893b2d6b8f9f06e716b3d
The report of repeated waveform agreement supplies method context for removing a shared additive block reference. The present score instead tests mean-removed residual waveforms between different named shafts in 80 selected groups.
- usesPost-pulse variation gave lower loss for separate 100 to 500 ms SEEG repeat gaps in seven selected patients after fixed correction and time mean removal sci:sha256:e75d82d6a39f40993d34a307cb1c454e73cf4720cf3c71ac4912db69967a56c0
This study uses the selected corrected voltage windows, fixed group and pulse selection, provenance, and source extraction code. It adds a residual correlation score between local signals on different shafts and an exact pulse-label benchmark. It reuses the same patients.
- usesA joint exchangeability test found excess adjacent residual waveform similarity mainly from one of seven SEEG patients sci:sha256:ad6f8dc239fe72f8796696b6308b400cbebe45bd6b425de58dc5ae41c50468c9
The report of residual pulse-order dependence informed the use of two five-pulse blocks and a stated arithmetic permutation benchmark. The present score tests matching pulses between different shafts rather than adjacent pulses within a contact.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The fixed selected SEEG data are from OpenNeuro ds004696 version 1.0.1; saved metadata records this exact version and its CC0 license.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.