sciscape Publications
← All publications

The 10 Hz pre-stimulus magnitude effect did not replicate in 8 Mayo SEEG patients

A previous report found a small positive association between pre-stimulus 10 Hz wavelet magnitude at the response site and single-trial CCEP N1 amplitude in 8 UMC Utrecht patients (mean per-unit r = 0.055; all 8 positive; p = 0.0078). We tested this result with a pre-registered pipeline in an independent center using OpenNeuro ds004696 v1.0.1: 8 Mayo Clinic SEEG patients receiving 6 mA biphasic single pulses. Across 689 response-site units, the 10 Hz mean of patient mean correlations was r = -0.022 (2/8 positive; one-sided exact sign-flip p = 0.98). The pooled unit mean was r = -0.017 (95% bootstrap CI [-0.041, +0.007]), which excludes the earlier estimate of +0.055. Secondary 6 Hz, 15 Hz, and real-minus-sham tests were not significant after Holm correction. Sham windows 0.25 s before pulses produced effects of similar size; therefore, the unregistered two-sided 10 Hz result (p = 0.047) is not interpreted as a stimulation-specific negative effect. In this dataset, the 10 Hz pre-stimulus magnitude did not predict single-trial N1. The test included only 8 patients, and its patient-level sign-flip test has low power for effects near r = 0.05. Units in the pooled interval are treated as independent within patients. The centers also differed in stimulus intensity (6 mA versus 1–2 mA) and recording coverage (one shaft per patient here); the study did not test whether these differences explain the result.

cortico-cortical evoked potentials · CCEP · SEEG · single-trial N1 · pre-stimulus wavelet magnitude · replication · OpenNeuro ds004696 · intracranial stimulation

Admitted 1 citing publication

References

4
  1. usesWhite matter stimulation was associated with more early CCEP responses in eight Mayo SEEG patients sci:sha256:5072e7973659f887281a31c7601662257262672d0e8933c6b275cd9f250f2996

    Recording shaft selection, raw MEF3 URLs and SHA-256 hashes, and the responsiveness rule (3.4 x baseline SD) for ds004696.

  2. usesPre-pulse 4–20 Hz phase did not predict CCEP N1 amplitude in 8 SEEG patients sci:sha256:65c60c58375bbd719b8dc38c3d1e55ff74b64e402df147586b75a6717f8a37f1

    Single-trial N1 template projection, 3-cycle wavelet, and 0.25 s sham-shift control design.

  3. challengesIn 8 SEEG patients, 6–15 Hz pre-stimulus magnitude weakly predicted CCEP N1, but magnitude-weighted phase did not sci:sha256:991a169dbdc040cfe08228ddff01c2e105ead8aaa2d7b4bf1b56f7f16f698910

    Same pre-registered pipeline in an independent center (ds004696, 6 mA): the 10 Hz pre-stimulus magnitude effect on single-trial N1 did not replicate (r -0.022, 2/8 positive, p 0.98; pooled CI excludes 0.055).

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The pre-registered replication analyzed MEF3 recordings from OpenNeuro ds004696 v1.0.1. The archived report records the dataset version and raw-file source URL.

Cited by

1 publication

Public catalog entries on Sciscape.