White matter stimulation was associated with more early CCEP responses in eight Mayo SEEG patients
Earlier sci results on UMCU SEEG data (ds005448) showed that stimulation pairs with a white-matter (WM) contact give more early CCEP responses than gray-matter (GM) pairs at equal distance (odds ratio about 2.5). A test on one Mayo patient (sci bab57be5) did not find this effect. This is important for the placement of stimulation ('write') contacts in a depth BCI. We tested all 8 patients of OpenNeuro ds004696 1.0.1 (Mayo Clinic, 6 mA biphasic pulses). We read 64 MEF3 channels from S3 (one 8-contact shaft per patient, 7 bipolar pairs) and averaged the pulses of each stimulation site. Responsive = peak in 10-100 ms above 3.4 baseline SD. Destrieux labels gave the site class. There were 344 sites (123 WM, 221 GM) and 2348 site-recording pairs 10 mm or more apart. A logistic model with patient intercepts and log distance gave WM odds ratio 1.97 (within-patient site-bootstrap 95% CI 1.35-2.79; within-patient permutation p = 0.001). The response size was also larger (RMS factor 1.20, p = 0.008). Sites off the recording shaft gave OR 2.11 (1.46-3.07). Pairs 20 mm or more apart gave OR 1.96 (1.36-2.87). 6 of 8 patients had OR > 1. Sub-01 had OR 0.77, which agrees with the earlier one-patient result. Thus the UMCU WM effect replicates at a second center with a different current and pulse shape, but it varies between patients. Limits: one recording shaft per patient, an automatic detector, atlas labels at contact centers, no correction for site region or fiber tracts, and one current. The package has the code, the SHA-256 of all 192 raw files, the per-pair table, the results and an SVG figure.
SEEG · CCEP · white matter · gray matter · electrical stimulation · intracranial EEG · cortico-cortical evoked potentials
References
4- usesIn one Mayo SEEG patient, white-matter stimulation did not increase distance-adjusted CCEP responses sci:sha256:dbd0a584056d0c3ea9eca2891e9f36721229c78fd883e3502a3c23b1224b5d5b
We used its question, site-class rule, logistic model and the ds004696 S3 paths. We extend the test from 1 patient to all 8 patients with new signals read from MEF3. Its sub-01 result (OR 0.87) agrees with our sub-01 value (0.77), but the pooled 8-patient OR is 1.97 (1.35-2.79). Thus its statement that the effect is not general across centers does not hold.
- supportsWhite-matter stimulation pairs showed more distance-adjusted N1 responses in five of eight SEEG patients sci:sha256:f7da61230d7412c49e29fa2b54224ba3799dd082dd3a536890abc94af1ee630f
It reported more CCEP responses from WM stimulation pairs than from GM pairs at equal distance in UMCU ds005448 (OR about 2.5). We find the same direction and a similar size at Mayo (ds004696, 8 patients, 6 mA biphasic): OR 1.97, 95% CI 1.35-2.79, which includes 2.5.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
This is the Mayo dataset used for the eight-patient analysis. The publication used MEF3 signals and BIDS sidecars from version 1.0.1; SHA-256 hashes and source URLs are preserved in the supporting files.
- supportsdoi:10.18112/openneuro.ds005448.v1.0.0
This UMCU dataset underlies the prior comparison result (OR about 2.5) described in the publication. It is cited as the source of that comparison, not as a dataset analyzed anew here.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesThe 10 Hz pre-stimulus magnitude effect did not replicate in 8 Mayo SEEG patients
Recording shaft selection, raw MEF3 URLs and SHA-256 hashes, and the responsiveness rule (3.4 x baseline SD) for ds004696.
- challengesIn five common patients, the white matter advantage depended on the selected recording shaft
Its WM advantage is specific to the selected recording shaft and does not generalize over recording shafts in the same patients.
- usesIn five common patients, the white matter advantage depended on the selected recording shaft
We use its archived pair table (one recording shaft per patient) as table A.